Merge "Update YANG models for OpenFronthaul M-Plane."
[sim/o1-interface.git] / ntsimulator / deploy / o-ran-ru-fh / yang / o-ran-fm@2019-02-04.yang
diff --git a/ntsimulator/deploy/o-ran-ru-fh/yang/o-ran-fm@2019-02-04.yang b/ntsimulator/deploy/o-ran-ru-fh/yang/o-ran-fm@2019-02-04.yang
deleted file mode 100644 (file)
index 5142418..0000000
+++ /dev/null
@@ -1,166 +0,0 @@
-module o-ran-fm {
-  yang-version 1.1;
-  namespace "urn:o-ran:fm:1.0";
-  prefix "o-ran-fm";
-
-  import ietf-yang-types {
-    prefix yang;
-    revision-date 2013-07-15;
-  }
-
-  organization "O-RAN Alliance";
-
-  contact
-    "www.o-ran.org";
-
-  description
-    "This module defines alarm reporting mechanism.
-
-    Copyright 2019 the O-RAN Alliance.
-
-    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS'
-    AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-    IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-    ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
-    LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
-    CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
-    SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
-    INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
-    CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
-    ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
-    POSSIBILITY OF SUCH DAMAGE.
-
-    Redistribution and use in source and binary forms, with or without
-    modification, are permitted provided that the following conditions are met:
-
-    * Redistributions of source code must retain the above copyright notice,
-    this list of conditions and the above disclaimer.
-    * Redistributions in binary form must reproduce the above copyright notice,
-    this list of conditions and the above disclaimer in the documentation
-    and/or other materials provided with the distribution.
-    * Neither the Members of the O-RAN Alliance nor the names of its
-    contributors may be used to endorse or promote products derived from
-    this software without specific prior written permission.";
-
-  revision "2019-02-04" {
-    description
-      "version 1.0.0
-
-      1) imported model from xRAN
-      2) changed namespace and reference from xran to o-ran";
-
-    reference "ORAN-WG4.M.0-v01.00";
-  }
-
-  grouping alarm {
-    description
-      "Gropuping which can uniquely identify alarm";
-
-    leaf fault-id {
-      type uint16;
-      mandatory true;
-
-      description
-        "Fault specific Id that identifies the fault.";
-    }
-
-    leaf fault-source {
-      type string {
-        length "1..255";
-      }
-      mandatory true;
-
-      description
-        "Represents the Object or source that is suspected to be faulty.";
-    }
-
-    list affected-objects {
-      leaf name {
-        type string {
-          length "1..255";
-        }
-        mandatory true;
-
-        description
-          "Represents the Object or source that is suspected to be affected by this fault";
-      }
-      min-elements 1;
-      max-elements 100;
-
-      description
-        "List of affected-objects";
-    }
-
-    leaf fault-severity {
-      type enumeration {
-        enum CRITICAL {
-          description
-            "Critical alarm means that this device is not able to perform any further service";
-        }
-        enum MAJOR {
-          description
-            "Major alarm appeared on the device";
-        }
-        enum MINOR {
-          description
-            "Minor alarm appeared on the device";
-        }
-        enum WARNING {
-          description
-            "Warning is being reported by the device";
-        }
-      }
-      mandatory true;
-
-      description
-        "Fault severity defines the severity level of the fault. A notification, whose fault severity has the value 'warning',
-        is a special type of an alarm notification. For these alarm notifications,
-        the Master Agent does not expect to receive a clear alarm notification.";
-    }
-
-    leaf is-cleared {
-      type boolean;
-      mandatory true;
-
-      description
-        "Fault state determines the type of the event. Not used if faultSeverity is WARNING.";
-    }
-
-    leaf fault-text {
-      type string {
-        length "0..255";
-      }
-
-      description
-        "Textual description of the fault.";
-    }
-
-    leaf event-time {
-      type yang:date-and-time;
-      mandatory true;
-
-      description
-        "Timestamp to indicate the time when the fault is detected/cleared.";
-    }
-  }
-
-  container active-alarm-list {
-    list active-alarms {
-      uses alarm;
-
-      description
-        "List of currenty active alarms";
-    }
-    config false;
-
-    description
-      "List of currently active alarms. An alarm is removed from this table when the state transitions to clear.";
-  }
-
-  notification alarm-notif {
-    uses alarm;
-
-    description
-      "Notification sent on initial alarm creation, as well as any time the alarm changes state, including clear";
-  }
-}