X-Git-Url: https://gerrit.o-ran-sc.org/r/gitweb?p=sim%2Fo1-interface.git;a=blobdiff_plain;f=ntsimulator%2Fdeploy%2Fo-ran-ru-fh%2Fyang%2Fo-ran-fm%402019-02-04.yang;fp=ntsimulator%2Fdeploy%2Fo-ran-ru-fh%2Fyang%2Fo-ran-fm%402019-02-04.yang;h=0000000000000000000000000000000000000000;hp=5142418229f9baaf7dfc99555e1eea13a60dc1dc;hb=f57d4764e3f681d216088f07088366a58f9adba3;hpb=7ff0c8ce9187702caa356c0c1f30064c65c1f512 diff --git a/ntsimulator/deploy/o-ran-ru-fh/yang/o-ran-fm@2019-02-04.yang b/ntsimulator/deploy/o-ran-ru-fh/yang/o-ran-fm@2019-02-04.yang deleted file mode 100644 index 5142418..0000000 --- a/ntsimulator/deploy/o-ran-ru-fh/yang/o-ran-fm@2019-02-04.yang +++ /dev/null @@ -1,166 +0,0 @@ -module o-ran-fm { - yang-version 1.1; - namespace "urn:o-ran:fm:1.0"; - prefix "o-ran-fm"; - - import ietf-yang-types { - prefix yang; - revision-date 2013-07-15; - } - - organization "O-RAN Alliance"; - - contact - "www.o-ran.org"; - - description - "This module defines alarm reporting mechanism. - - Copyright 2019 the O-RAN Alliance. - - THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' - AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE - IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE - ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE - LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR - CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF - SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS - INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN - CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) - ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE - POSSIBILITY OF SUCH DAMAGE. - - Redistribution and use in source and binary forms, with or without - modification, are permitted provided that the following conditions are met: - - * Redistributions of source code must retain the above copyright notice, - this list of conditions and the above disclaimer. - * Redistributions in binary form must reproduce the above copyright notice, - this list of conditions and the above disclaimer in the documentation - and/or other materials provided with the distribution. - * Neither the Members of the O-RAN Alliance nor the names of its - contributors may be used to endorse or promote products derived from - this software without specific prior written permission."; - - revision "2019-02-04" { - description - "version 1.0.0 - - 1) imported model from xRAN - 2) changed namespace and reference from xran to o-ran"; - - reference "ORAN-WG4.M.0-v01.00"; - } - - grouping alarm { - description - "Gropuping which can uniquely identify alarm"; - - leaf fault-id { - type uint16; - mandatory true; - - description - "Fault specific Id that identifies the fault."; - } - - leaf fault-source { - type string { - length "1..255"; - } - mandatory true; - - description - "Represents the Object or source that is suspected to be faulty."; - } - - list affected-objects { - leaf name { - type string { - length "1..255"; - } - mandatory true; - - description - "Represents the Object or source that is suspected to be affected by this fault"; - } - min-elements 1; - max-elements 100; - - description - "List of affected-objects"; - } - - leaf fault-severity { - type enumeration { - enum CRITICAL { - description - "Critical alarm means that this device is not able to perform any further service"; - } - enum MAJOR { - description - "Major alarm appeared on the device"; - } - enum MINOR { - description - "Minor alarm appeared on the device"; - } - enum WARNING { - description - "Warning is being reported by the device"; - } - } - mandatory true; - - description - "Fault severity defines the severity level of the fault. A notification, whose fault severity has the value 'warning', - is a special type of an alarm notification. For these alarm notifications, - the Master Agent does not expect to receive a clear alarm notification."; - } - - leaf is-cleared { - type boolean; - mandatory true; - - description - "Fault state determines the type of the event. Not used if faultSeverity is WARNING."; - } - - leaf fault-text { - type string { - length "0..255"; - } - - description - "Textual description of the fault."; - } - - leaf event-time { - type yang:date-and-time; - mandatory true; - - description - "Timestamp to indicate the time when the fault is detected/cleared."; - } - } - - container active-alarm-list { - list active-alarms { - uses alarm; - - description - "List of currenty active alarms"; - } - config false; - - description - "List of currently active alarms. An alarm is removed from this table when the state transitions to clear."; - } - - notification alarm-notif { - uses alarm; - - description - "Notification sent on initial alarm creation, as well as any time the alarm changes state, including clear"; - } -}