Initial commit of the O1 simulator framework.
[sim/o1-interface.git] / ntsimulator / yang / o-ran-fm.yang
diff --git a/ntsimulator/yang/o-ran-fm.yang b/ntsimulator/yang/o-ran-fm.yang
new file mode 100644 (file)
index 0000000..92238aa
--- /dev/null
@@ -0,0 +1,168 @@
+module o-ran-fm {
+  yang-version 1.1;
+  namespace "urn:o-ran:fm:1.0";
+  prefix "o-ran-fm";
+
+  import ietf-yang-types {
+    prefix yang;
+    revision-date 2013-07-15;
+  }
+
+  organization "O-RAN Alliance";
+
+  contact
+    "www.o-ran.org";
+
+  description
+    "This module defines alarm reporting mechanism.
+
+    Copyright 2019 the O-RAN Alliance.
+
+    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS'
+    AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
+    IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
+    ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
+    LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
+    CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
+    SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
+    INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
+    CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+    ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+    POSSIBILITY OF SUCH DAMAGE.
+
+    Redistribution and use in source and binary forms, with or without
+    modification, are permitted provided that the following conditions are met:
+
+    * Redistributions of source code must retain the above copyright notice,
+    this list of conditions and the above disclaimer.
+    * Redistributions in binary form must reproduce the above copyright notice,
+    this list of conditions and the above disclaimer in the documentation
+    and/or other materials provided with the distribution.
+    * Neither the Members of the O-RAN Alliance nor the names of its
+    contributors may be used to endorse or promote products derived from
+    this software without specific prior written permission.";
+
+  revision "2019-02-04" {
+    description
+      "version 1.0.0
+
+      1) imported model from xRAN
+      2) changed namespace and reference from xran to o-ran";
+
+    reference "ORAN-WG4.M.0-v01.00";
+  }
+
+  grouping alarm {
+    description
+      "Gropuping which can uniquely identify alarm";
+
+    leaf fault-id {
+      type uint16;
+      mandatory true;
+
+      description
+        "Fault specific Id that identifies the fault.";
+    }
+
+    leaf fault-source {
+      type string {
+        length "1..255";
+      }
+      mandatory true;
+
+      description
+        "Represents the Object or source that is suspected to be faulty.";
+    }
+
+    list affected-objects {
+      key name;
+      leaf name {
+        type string {
+          length "1..255";
+        }
+        mandatory true;
+
+        description
+          "Represents the Object or source that is suspected to be affected by this fault";
+      }
+      min-elements 1;
+      max-elements 100;
+
+      description
+        "List of affected-objects";
+    }
+
+    leaf fault-severity {
+      type enumeration {
+        enum CRITICAL {
+          description
+            "Critical alarm means that this device is not able to perform any further service";
+        }
+        enum MAJOR {
+          description
+            "Major alarm appeared on the device";
+        }
+        enum MINOR {
+          description
+            "Minor alarm appeared on the device";
+        }
+        enum WARNING {
+          description
+            "Warning is being reported by the device";
+        }
+      }
+      mandatory true;
+
+      description
+        "Fault severity defines the severity level of the fault. A notification, whose fault severity has the value 'warning',
+        is a special type of an alarm notification. For these alarm notifications,
+        the Master Agent does not expect to receive a clear alarm notification.";
+    }
+
+    leaf is-cleared {
+      type boolean;
+      mandatory true;
+
+      description
+        "Fault state determines the type of the event. Not used if faultSeverity is WARNING.";
+    }
+
+    leaf fault-text {
+      type string {
+        length "0..255";
+      }
+
+      description
+        "Textual description of the fault.";
+    }
+
+    leaf event-time {
+      type yang:date-and-time;
+      mandatory true;
+
+      description
+        "Timestamp to indicate the time when the fault is detected/cleared.";
+    }
+  }
+
+  container active-alarm-list {
+    list active-alarms {
+      key fault-id;
+      uses alarm;
+
+      description
+        "List of currenty active alarms";
+    }
+    config false;
+
+    description
+      "List of currently active alarms. An alarm is removed from this table when the state transitions to clear.";
+  }
+
+  notification alarm-notif {
+    uses alarm;
+
+    description
+      "Notification sent on initial alarm creation, as well as any time the alarm changes state, including clear";
+  }
+}