Update use-cases.rst with info about ONAP policy solution 50/6350/1
authorRehanRaza <muhammad.rehan.raza@est.tech>
Fri, 18 Jun 2021 08:55:59 +0000 (10:55 +0200)
committerRehanRaza <muhammad.rehan.raza@est.tech>
Fri, 18 Jun 2021 08:56:03 +0000 (10:56 +0200)
Change-Id: Idc9ced3176d03ed86cd06058d4b811a78e88fbbb
Issue-ID: NONRTRIC-535
Signed-off-by: RehanRaza <muhammad.rehan.raza@est.tech>
docs/use-cases.rst

index dabcf62..4cbbed9 100644 (file)
@@ -21,8 +21,8 @@ For more information about it, see the README file in the use case's folder.
 O-RU closed loop recovery
 -------------------------
 
 O-RU closed loop recovery
 -------------------------
 
-This use case is a non-real-world closed-loop use case to demonstrate automated recovery when the front-haul connection between and O-DU and O-RU is reset. 
-An application in the NONRTRIC sense the fault from the O-RU (O1-FM) and initiates a NETCONF reset operation (O1-CM) using the OAM controller. 
+This use case is a non-real-world closed-loop use case to demonstrate automated recovery when the front-haul connection between an O-DU and O-RU is reset. 
+An application in the NONRTRIC senses the fault from the O-RU (O1-FM) and initiates a NETCONF reset operation (O1-CM) using the OAM controller. 
 More details about the use case can be found on the O-RAN SC wiki: `(RSAC) <https://wiki.o-ran-sc.org/pages/viewpage.action?pageId=20878423>`_ and `(OAM) <https://wiki.o-ran-sc.org/display/OAM/Closed+loop+use+case>`_.
 
 Non-RT RIC provides two implementation versions of the recovery part of the use case. One in the form of a python
 More details about the use case can be found on the O-RAN SC wiki: `(RSAC) <https://wiki.o-ran-sc.org/pages/viewpage.action?pageId=20878423>`_ and `(OAM) <https://wiki.o-ran-sc.org/display/OAM/Closed+loop+use+case>`_.
 
 Non-RT RIC provides two implementation versions of the recovery part of the use case. One in the form of a python
@@ -36,7 +36,19 @@ change messages sent from the script and responds with alarm cleared messages to
 
 All parts are Dockerized and can be started as individual containers, in the same network, in Docker.
 
 
 All parts are Dockerized and can be started as individual containers, in the same network, in Docker.
 
+The script based solution can be found in
+this `link <https://gerrit.o-ran-sc.org/r/gitweb?p=nonrtric.git;a=tree;f=test/usecases/oruclosedlooprecovery/scriptversion;b=HEAD>`_.
+
 ONAP Policy Solution
 ++++++++++++++++++++
 
 ONAP Policy Solution
 ++++++++++++++++++++
 
-**<ToDo>**
\ No newline at end of file
+There is also another solution for performing the fronthaul recovery that is based on ONAP Policy Framework.
+A TOSCA Policy has been created that listens to DMaaP Message Router and sends a configuration change message via
+REST call to the OAM controller. The policy based solution can be
+found `here <https://gerrit.o-ran-sc.org/r/gitweb?p=nonrtric.git;a=tree;f=test/usecases/oruclosedlooprecovery/apexpolicyversion;b=HEAD>`_.
+
+There is a `docker-compose <https://gerrit.o-ran-sc.org/r/gitweb?p=nonrtric.git;a=tree;f=docker-compose/docker-compose-policy-framework;b=HEAD>`_ available
+in the nonrtric repo for bringing up the complete standalone version of ONAP Policy Framework.
+
+The detailed instructions for deploying and running this policy are provided in
+the `wiki <https://wiki.o-ran-sc.org/pages/viewpage.action?pageId=35881325>`_.
\ No newline at end of file