-event:
- presence: required
- structure:
- commonEventHeader:
- presence: required
- structure:
- domain: {presence: required, value: notification}
- eventName: {presence: required, value: Noti_MyPnf-Acme_FileReady}
- priority: {presence: required, value: Normal}
- eventId: {presence: required}
- reportingEntityId: {presence: required}
- reportingEntityName: {presence: required}
- sequence: {presence: required, value: 0}
- sourceId: {presence: required}
- sourceName: {presence: required}
- version: {presence: required, value: 4.0.1}
- vesEventListenerVersion: {presence: required, value: 7.0.1}
- startEpochMicrosec: {presence: required}
- lastEpochMicrosec: {presence: required}
- notificationFields:
- presence: required
- structure:
- changeIdentifier: {presence: required, value: PM_MEAS_FILES}
- changeType: {presence: required, value: fileReady}
- notificationFieldsVersion: {presence: required, value: 2.0}
- arrayOfNamedHashMap:
- presence: required
- array:
- - name: {presence: required}
- hashMap: {presence: required, structure: {
- keyValuePair: {presence: required, structure: {key: {presence: required, value: location}, value: {presence: required}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: compression}, value: {presence: required, value: gzip}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: fileFormatType}, value: {presence: required, value: org.3GPP.32.435}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: fileFormatVersion}, value: {presence: required, value: V10}}}}
- }
-...
----
-event:
- presence: required
- structure:
- commonEventHeader:
- presence: required
- structure:
- domain: {presence: required, value: pnfRegistration}
- eventId: {presence: required}
- eventName: {presence: required, value: PnfReg_MyPnf-Acme_pnfRegistration}
- lastEpochMicrosec: {presence: required}
- priority: {presence: required, value: Normal}
- reportingEntityName: {presence: required}
- sequence: {presence: required, value: 0}
- sourceName: {presence: required}
- startEpochMicrosec: {presence: required}
- timeZoneOffset: {presence: required}
- version: {presence: required, value: 4.0.1}
- vesEventListenerVersion: {presence: required, value: 7.0.1}
- pnfRegistrationFields:
- presence: required
- structure:
- modelNumber: {presence: required}
- oamV4IpAddress: {presence: optional}
- oamV6IpAddress: {presence: optional}
- pnfRegistrationFieldsVersion: {presence: required, value: 2.0}
- serialNumber: {presence: required}
- softwareVersion: {presence: required}
- unitFamily: {presence: required, value: BBU}
- unitType: {presence: required}
- vendorName: {presence: required, value: Acme}
-...
----
-event:
- presence: required
- action: [ any, any, null, null, null ]
- comment: "
- ALARM NAME: CertMAutomaticEnrollmentFailed,
- ALARM DESCRIPTION: ‘See alarm OPI x/1111-ABC 123 4567/1 Uen’,
- ALARM EFFECT: 'See alarm OPI x/2222-ABC 123 4567/1 Uen',
- MANAGED OBJECT CLASSES: NodeCredential,
- EVENT TYPE: 'PROCESSINGERRORALARM',
- PROBABLE CAUSE: 'ConfigurationOrCustomizationError',
- PROPOSED REPAIR ACTIONS: 'See alarm OPI x/3333-ABC 123 4567/1 Uen',
- CLEARING TYPE: Automatic
- "
- structure:
- commonEventHeader:
- presence: required
- structure:
- version: {presence: required, value: 4.0.1}
- vesEventListenerVersion: {presence: required, value: 7.0.1}
- domain: {presence: required, value: fault}
- eventName: {presence: required, value: Fault_MyPnf-Acme_CertMAutomaticEnrollmentFailed}
- eventId: {presence: required}
- sequence: {presence: required}
- priority: {presence: required, value: Normal}
- reportingEntityName: {presence: required}
- sourceName: {presence: required}
- nfVendorName: {presence: required, value: Acme}
- startEpochMicrosec: {presence: required}
- lastEpochMicrosec: {presence: required}
- timeZoneOffset: {presence: required}
- faultFields:
- presence: required
- structure:
- faultFieldsVersion: {presence: required, value: 4.0}
- alarmCondition: {presence: required, value: 'CertMAutomaticEnrollmentFailed'}
- eventCategory: {presence: required, value: 'PROCESSINGERRORALARM'}
- eventSourceType: {presence: required}
- specificProblem: {presence: required, value: 'Certificate Management Automatic Enrollment Failed'}
- eventSeverity: {presence: required}
- vfStatus: {presence: required, value: Active}
- alarmAdditionalInformation: {presence: required, structure: {
- keyValuePair: {presence: required, structure: {key: {presence: required, value: source}, value: {presence: required}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: probableCause}, value: {presence: required, value: 'ConfigurationOrCustomizationError'}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalText}, value: {presence: optional}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalInfo}, value: {presence: optional}}}}
- }
-...
----
-event:
- presence: required
- action: [ any, any, null, null, null ]
- comment: "
- ALARM NAME: PowerLoss,
- ALARM DESCRIPTION: 'PNF is losing power',
- ALARM EFFECT: 'PNF will shutdown if battery is drained',
- MANAGED OBJECT CLASSES: 'BatteryBackup;BatteryUnit',
- EVENT TYPE: 'EQUIPMENTALARM',
- PROBABLE CAUSE: 'Power Supply Failure',
- PROPOSED REPAIR ACTIONS: 'Repair Power Supply',
- CLEARING TYPE: Automatic
- "
- structure:
- commonEventHeader:
- presence: required
- structure:
- version: {presence: required, value: 4.0.1}
- vesEventListenerVersion: {presence: required, value: 7.0.1}
- domain: {presence: required, value: fault}
- eventName: {presence: required, value: Fault_MyPnf-Acme_PowerLoss}
- eventId: {presence: required}
- sequence: {presence: required}
- priority: {presence: required, value: Normal}
- reportingEntityName: {presence: required}
- sourceName: {presence: required}
- nfVendorName: {presence: required, value: Acme}
- startEpochMicrosec: {presence: required}
- lastEpochMicrosec: {presence: required}
- timeZoneOffset: {presence: required}
- faultFields:
- presence: required
- structure:
- faultFieldsVersion: {presence: required, value: 4.0}
- alarmCondition: {presence: required, value: 'PowerLoss'}
- eventCategory: {presence: required, value: 'EQUIPMENTALARM'}
- eventSourceType: {presence: required}
- specificProblem: {presence: required, value: 'Power Supply Failure'}
- eventSeverity: {presence: required}
- vfStatus: {presence: required, value: Active}
- alarmAdditionalInformation: {presence: required, structure: {
- keyValuePair: {presence: required, structure: {key: {presence: required, value: source}, value: {presence: required}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: probableCause}, value: {presence: required, value: 'Power Supply Failure'}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalText}, value: {presence: optional}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalInfo}, value: {presence: optional}}}}
- }
-...
----
-event:
- presence: required
- action: [ any, any, null, null, null ]
- comment: "
- ALARM NAME: LogHasReachedFullCapacity,
- ALARM DESCRIPTION: 'Log Has Reached Full Capacity',
- ALARM EFFECT: 'See alarm OPI x/2223-ABC 123 4567/1 Uen',
- MANAGED OBJECT CLASSES: Log,
- EVENT TYPE: 'PROCESSINGERRORALARM',
- PROBABLE CAUSE: 'FileError',
- PROPOSED REPAIR ACTIONS: 'See alarm OPI x/3334-ABC 123 4567/1 Uen',
- CLEARING TYPE: Automatic
- "
- structure:
- commonEventHeader:
- presence: required
- structure:
- version: {presence: required, value: 4.0.1}
- vesEventListenerVersion: {presence: required, value: 7.0.1}
- domain: {presence: required, value: fault}
- eventName: {presence: required, value: Fault_MyPnf-Acme_LogHasReachedFullCapacity}
- eventId: {presence: required}
- sequence: {presence: required}
- priority: {presence: required, value: Normal}
- reportingEntityName: {presence: required}
- sourceName: {presence: required}
- nfVendorName: {presence: required, value: Acme}
- startEpochMicrosec: {presence: required}
- lastEpochMicrosec: {presence: required}
- timeZoneOffset: {presence: required}
- faultFields:
- presence: required
- structure:
- faultFieldsVersion: {presence: required, value: 4.0}
- alarmCondition: {presence: required, value: 'LogHasReachedFullCapacity'}
- eventCategory: {presence: required, value: 'PROCESSINGERRORALARM'}
- eventSourceType: {presence: required}
- specificProblem: {presence: required, value: 'Log Has Reached Full Capacity'}
- eventSeverity: {presence: required}
- vfStatus: {presence: required, value: Active}
- alarmAdditionalInformation: {presence: required, structure: {
- keyValuePair: {presence: required, structure: {key: {presence: required, value: source},value: {presence: required}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: probableCause},value: {presence: required, value: 'FileError'}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalText},value: {presence: optional}}},
- keyValuePair: {presence: required, structure: {key: {presence: required, value: additionalInfo},value: {presence: optional}}}}
- }
-...