X-Git-Url: https://gerrit.o-ran-sc.org/r/gitweb?a=blobdiff_plain;f=data-model%2Fyang%2Fsim%2Fx-ran%2Fx-ran-ru-fh%2Fxran-alarm-id.yang;fp=data-model%2Fyang%2Fsim%2Fx-ran%2Fx-ran-ru-fh%2Fxran-alarm-id.yang;h=0000000000000000000000000000000000000000;hb=de45148a9aec4652465c8c4c7723177a6059ad93;hp=f87fcea08c0291583cafd33043953aefd4baa50a;hpb=20487cc1310362d9bc165c66397c7fc14b4ca938;p=scp%2Foam%2Fmodeling.git diff --git a/data-model/yang/sim/x-ran/x-ran-ru-fh/xran-alarm-id.yang b/data-model/yang/sim/x-ran/x-ran-ru-fh/xran-alarm-id.yang deleted file mode 100644 index f87fcea..0000000 --- a/data-model/yang/sim/x-ran/x-ran-ru-fh/xran-alarm-id.yang +++ /dev/null @@ -1,178 +0,0 @@ -module xran-alarm-id { - yang-version 1.1; - namespace "urn:xran:alarms:1.0"; - prefix "xran-alarms"; - - organization "xRAN Forum"; - - contact - "www.xran.org"; - - description - "This module defines the alarm identities for the RU. - - Copyright 2018 the xRAN Forum. - - THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' - AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE - IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE - ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE - LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR - CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF - SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS - INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN - CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) - ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE - POSSIBILITY OF SUCH DAMAGE. - - Redistribution and use in source and binary forms, with or without - modification, are permitted provided that the following conditions are met: - - * Redistributions of source code must retain the above copyright notice, - this list of conditions and the above disclaimer. - * Redistributions in binary form must reproduce the above copyright notice, - this list of conditions and the above disclaimer in the documentation - and/or other materials provided with the distribution. - * Neither the Members of the xRAN Forum nor the names of its - contributors may be used to endorse or promote products derived from - this software without specific prior written permission."; - - revision "2018-07-20" { - description - "version 1.0.0 - First release of the xRAN YANG M-Plane models. - - This version of the model supports v01.00 of the corrsponding xRAN - M-Plane Specification."; - reference "XRAN-FH.MP.0-v01.00"; - } - - typedef alarm-id { - type enumeration { - enum XRAN_HIGH_TEMP_ALARM { - value 1; - description "A temperature is higher than expected"; - } - enum XRAN_OVERHEATING_ALARM { - value 2; - description "A temperature is dangerously high"; - } - enum XRAN_AMBIENT_TEMP_ALARM { - value 3; - description "A temperature related alarm due to ambient temperature - value going outside the allowed ambient temperature range"; - } - enum XRAN_TEMP_TOO_LOW_ALARM { - value 4; - description "A temperature related alarm due to the temperature inside - the unit being too low"; - } - enum XRAN_BROKEN_FAN_ALARM { - value 5; - description "A broken fan"; - } - enum XRAN_FAN_NOT_DETECTED_ALARM { - value 6; - description "A fan not detected"; - } - enum XRAN_TUNING_ALARM { - value 7; - description "A tuning failure."; - } - enum XRAN_FILTER_ALARM { - value 8; - description "A faulty filter."; - } - enum XRAN_TX_QUALITY_ALARM { - value 9; - description "A transmission quality."; - } - enum XRAN_OVERVOLTAGE_ALARM { - value 10; - description "A RF overvoltage protection."; - } - enum XRAN_CONFIG_ALARM { - value 11; - description "A configuration failed."; - } - enum XRAN_CRITICAL_FILE_ALARM { - value 12; - description "A Critical file not found."; - } - enum XRAN_FILE_ALARM { - value 13; - description "A non-critical file not found."; - } - enum XRAN_CORRUPT_FILE_ALARM { - value 14; - description "A corrupt configuration file."; - } - enum XRAN_OPERATION_ALARM { - value 15; - description "A unit out of order."; - } - enum XRAN_NO_IDENTITY_ALARM { - value 16; - description "A unit cannot be identified."; - } - enum XRAN_NO_EXT_SYNC_SOURCE { - value 17; - description "An RU has no external sync source."; - } - enum XRAN_SYNC_ALARM { - value 18; - description "A unit is out of synchronization."; - } - enum XRAN_TX_OUT_OF_ORDER_ALARM { - value 19; - description "A TX path is not usable."; - } - enum XRAN_RX_OUT_OF_ORDER_ALARM { - value 20; - description "A RX path is not usable."; - } - enum XRAN_OPTICAL_BER_ALARM { - value 21; - description "An increased bit error rate on the optical link"; - } - enum XRAN_SELF_TEST_ALARM { - value 22; - description "A power-on self test"; - } - enum XRAN_FPGA_UPDATE_ALARM { - value 23; - description "An FPGA software update"; - } - enum XRAN_UNIT_BLOCKED_ALARM { - value 24; - description "A unit is blocked"; - } - enum XRAN_RESET_REQUEST_ALARM { - value 25; - description "A unit requires a reset"; - } - enum XRAN_POWER_SUPPLY_FAULTY { - value 26; - description "A power supply unit has a fault"; - } - enum XRAN_POWER_AMPLIFIER_FAULTY { - value 27; - description "A power amplifier unit has a fault"; - } - enum XRAN_C_U_PLANE_LOGICAL_CONNECTION_FAULTY { - value 28; - description "A C/U-plane logical connection has a fault"; - } - enum XRAN_TRANSCEIVER_FAULT { - value 29; - description "A transceiver unit has a fault"; - } - enum XRAN_INTERFACE_FAULT { - value 30; - description "An interface unit has a fault"; - } - } - description - "A typedef defining an enumerated list of XRAN alarms which corresponds to - the fault-id in the xran management plane specification."; - } -}