X-Git-Url: https://gerrit.o-ran-sc.org/r/gitweb?a=blobdiff_plain;f=data-model%2Fyang%2Fpublished%2Fo-ran%2Fru-fh%2Fo-ran-transceiver.yang;h=ca3e9906e846e811738739ea659991730e05541a;hb=HEAD;hp=93d83d8941d5ef619d5219d08854624a9a13a836;hpb=7540aac9279c5ed8140850e19381dc06fefafec1;p=scp%2Foam%2Fmodeling.git diff --git a/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang b/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang deleted file mode 100644 index 93d83d8..0000000 --- a/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang +++ /dev/null @@ -1,513 +0,0 @@ -module o-ran-transceiver { - yang-version 1.1; - namespace "urn:o-ran:transceiver:1.0"; - prefix "o-ran-transceiver"; - - import o-ran-interfaces { - prefix "o-ran-int"; - } - - import ietf-interfaces { - prefix "if"; - } - - organization "O-RAN Alliance"; - - contact - "www.o-ran.org"; - - description - "This module defines the operational state data for SFP transceivers used in - an O-RAN Radio Unit. - - Copyright 2019 the O-RAN Alliance. - - THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' - AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE - IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE - ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE - LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR - CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF - SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS - INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN - CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) - ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE - POSSIBILITY OF SUCH DAMAGE. - - Redistribution and use in source and binary forms, with or without - modification, are permitted provided that the following conditions are met: - - * Redistributions of source code must retain the above copyright notice, - this list of conditions and the above disclaimer. - * Redistributions in binary form must reproduce the above copyright notice, - this list of conditions and the above disclaimer in the documentation - and/or other materials provided with the distribution. - * Neither the Members of the O-RAN Alliance nor the names of its - contributors may be used to endorse or promote products derived from - this software without specific prior written permission."; - - revision "2019-07-03" { - description - "version 2.0.0 - - 1) introduction of reporting for QSFP. - 2) backward compatible changes to introduce groupings."; - - reference "ORAN-WG4.M.0-v02.00"; - } - - revision "2019-02-04" { - description - "version 1.0.0 - - 1) imported model from xRAN - 2) changed namespace and reference from xran to o-ran"; - - reference "ORAN-WG4.M.0-v01.00"; - } - - - // Groupings - - grouping transceiver-group { - list port-transceiver-data { - key "interface-name port-number"; - description "data recovered from port transceivers"; - leaf interface-name { - type leafref { - path "/if:interfaces/if:interface/if:name"; - } - description "Name of interface"; - } - leaf port-number { - type leafref { - path "/if:interfaces/if:interface[if:name = current()/../interface-name]" + "/o-ran-int:port-reference/o-ran-int:port-number"; - } - description - "A number which identifies a port. In case of SFP/SFP+ - port, port number value is 0 to N-1 where N is number of ports - in the device. Numbers 0 to N-1 are assigned to ports in order - following order of labels on the device (labels for ports are - not necessarily numbers starting from zero)"; - } - - leaf name { - type string { - length "1..255"; - } - description - "A name that is unique across the O-RU that identifies a transceiver instance. - This name may be used in fault management to refer to a fault source - or affected object"; - } - - leaf present { - type boolean; - config false; - mandatory true; - description - "Indicates if pluggable transceiver module is present."; - } - - leaf vendor-id { - type string { - length 1..16; - } - config false; - description - "Name of the transciever vendor Full name of transceiver vendor, - that contains ASCII characters, left-aligned with - any padding on the right with ASCII spaces (20h), or ASCII nul - (00h) removed, and ASCII less-than (3Ch) replaced with ASCII - open-brace (7Bh) and ASCII more-than (3Eh) replaced with ASCII - close-brace (7Dh). - - Optional node included when the NETCONF Server has determined - the vendor ID."; - } - - leaf vendor-part { - type string { - length 1..16; - } - config false; - description - "Transceiver vendors part number, that contains ASCII characters, - left-aligned with any padding on the right with ASCII spaces - (20h), or ASCII nul (00h) removed, and ASCII less-than (3Ch) - replaced with ASCII open-brace (7Bh) and ASCII more-than (3Eh) - replaced with ASCII close-brace (7Dh). - - Optional node included when the NETCONF Server has determined - the vendor part number."; - } - - leaf vendor-rev { - type string { - length 1..2; - } - config false; - description - "Transceiver vendors revision number. 2-octet field that - contains ASCII characters. - - Optional node included when the NETCONF Server has determined - the vendor revision number"; - } - - leaf serial-no { - type string { - length 1..16; - } - config false; - description - "Transceiver serial number encoded using ASCII characters, - left-aligned with any padding on the right with ASCII spaces - (20h), or ASCII nul (00h) removed, and ASCII less-than (3Ch) - replaced with ASCII open-brace (7Bh) and ASCII more-than (3Eh) - replaced with ASCII close-brace (7Dh). - - Optional node included when the NETCONF Server has determined - the serial number."; - } - - leaf SFF8472-compliance-code { - type enumeration { - enum diagnostics-undefined { - description "undefined compliance code"; - } - enum rev9.3-diagnostics { - description "diagnostics published 08-01-02"; - } - enum rev9.5-diagnostics{ - description "diagnostics published 06-01-04"; - } - enum rev10.2-diagnostics{ - description "diagnostics published 06-01-07"; - } - enum rev11.0-diagnostics{ - description "diagnostics published 05-21-10"; - } - enum rev11.3-diagnostics{ - description "diagnostics published 06-11-13"; - } - enum rev11.4-diagnostics{ - description "diagnostics published 07-24-14"; - } - enum rev12.0-diagnostics{ - description "diagnostics published 08-28-14"; - } - } - config false; - description - "Indication of which feature set(s) are - implemented in the transceiver from Byte 94 of address A0h - https://ta.snia.org/higherlogic/ws/public/download/294/SFF-8472.PDF - - Optional node included when the NETCONF Server has determined - the compliance code."; - - reference "https://ta.snia.org/higherlogic/ws/public/download/294/SFF-8472.PDF"; - } - - leaf connector-type { - type enumeration { - enum unknown { - description "encoded as 00h in Table 4-3 of SFF-8024"; - } - enum subscrber-connector { - description "encoded as 01h in Table 4-3 of SFF-8024"; - } - enum fiber-jack { - description "encoded as 06h in Table 4-3 of SFF-8024"; - } - enum lucent-connector { - description "encoded as 07h in Table 4-3 of SFF-8024"; - } - enum mt-rj { - description "encoded as 08h in Table 4-3 of SFF-8024"; - } - enum multiple-optical { - description "encoded as 09h in Table 4-3 of SFF-8024"; - } - enum sg { - description "encoded as 0Ah in Table 4-3 of SFF-8024"; - } - enum optical-pigtail { - description "encoded as 0Bh in Table 4-3 of SFF-8024"; - } - enum multi-fiber-parralel-optic-1x12 { - description "encoded as 0Ch in Table 4-3 of SFF-8024"; - } - enum multi-fiber-parralel-optic-2x16 { - description "encoded as 0Dh in Table 4-3 of SFF-8024"; - } - enum hssdc_2{ - description "encoded as 20h in Table 4-3 of SFF-8024"; - } - enum copper-pigtail{ - description "encoded as 21h in Table 4-3 of SFF-8024"; - } - enum rj45{ - description "encoded as 22h in Table 4-3 of SFF-8024"; - } - enum no-separable-connector{ - description "encoded as 23h in Table 4-3 of SFF-8024"; - } - enum mxc-2x16{ - description "encoded as 24h in Table 4-3 of SFF-8024"; - } - } - config false; - // TOCHECK: Remove any enumerations which are not applicable - description - "Connector-type indicates the external optical or electrical cable - connector provided as the media interface as defined in the connector - types derived from table 4-3 in SFF-8024. - - Optional node included when the NETCONF Server has determined - the connector type."; - reference "https://ta.snia.org/higherlogic/ws/public/document?document_id=944"; - } - - leaf identifier { - type enumeration { - enum unknown { - description "encoded as 00h in Table 4-1 of SFF-8024"; - } - enum gbic { - description "encoded as 01h in Table 4-1 of SFF-8024"; - } - enum soldered { - description "encoded as 02h in Table 4-1 of SFF-8024"; - } - enum sfp { - description "encoded as 03h in Table 4-1 of SFF-8024"; - } - enum xbi { - description "encoded as 04h in Table 4-1 of SFF-8024"; - } - enum xenpack { - description "encoded as 05h in Table 4-1 of SFF-8024"; - } - enum xfp { - description "encoded as 06h in Table 4-1 of SFF-8024"; - } - enum xff { - description "encoded as 07h in Table 4-1 of SFF-8024"; - } - enum xfp-e { - description "encoded as 08h in Table 4-1 of SFF-8024"; - } - enum xpak { - description "encoded as 09h in Table 4-1 of SFF-8024"; - } - enum x2 { - description "encoded as 0Ah in Table 4-1 of SFF-8024"; - } - enum dwdm-sfp { - description "encoded as 0Bh in Table 4-1 of SFF-8024"; - } - enum qsfp { - description "encoded as 0Ch in Table 4-1 of SFF-8024"; - } - enum qsfp+ { - description "encoded as 0Dh in Table 4-1 of SFF-8024"; - } - } - config false; - description - "Connector identifier as defined in the identifer - types derived from table 4-1 in SFF-8024. - - Optional node included when the NETCONF Server has determined - the identifier type."; - reference "https://members.snia.org/document/dl/26423"; - } - - leaf nominal-bitrate { - type uint32; - config false; - description - "Nominal bitrate in Mb/s (10^6 bits per second). - If needed actual value is rounded to nearest integer. - - Optional node included when the NETCONF Server has determined - the nominal bit rate."; - } - - leaf low-bitrate-margin { - type uint8; - config false; - description - "Minimum supported bitrate as percentage of nominal bitrate - below nominal bitrate. - - Optional node included when the NETCONF Server has determined - the low bit rate margin"; - } - - leaf high-bitrate-margin { - type uint8; - config false; - description - "Maximum supported bitrate as percentage of nominal bitrate - above nominal bitrate. - - Optional node included when the NETCONF Server has determined - the high bitrate margin."; - } - - leaf rx-power-type { - type enumeration { - enum oma { - description "oma = optical modulation amplitude"; - } - enum avp{ - description "avp = average power"; - } - } - config false; - description - "Receieved power measurement type - oma = optical modulation amplitude - avp = average power - - Optional node included when the NETCONF Server has determined - the rx power type."; - } - - leaf rx-power { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured RX input power in mW. - - Optional node included when the NETCONF Server has determined - the measured RX power. - - If operating with QSFP, this power corresponds to that of - Lane/Channel 1."; - } - - leaf tx-power { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured coupled TX output power in mW. - - Optional node included when the NETCONF Server has determined - the measured coupled TX power."; - } - - leaf tx-bias-current { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured transmitter laser bias current in mA. - - Optional node included when the NETCONF Server has determined - the tx bias current. - - If operating with QSFP, this bias current corresponds to that of - Lane/Channel 1."; - } - - leaf voltage { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Internally measured supply voltage in mV. - - Optional node included when the NETCONF Server has determined - the internally measured voltage."; - } - - leaf temperature { - type decimal64 { - fraction-digits 4; - } - config false; - description - "Internally measured module temperature in degrees Celcius. - - Optional node included when the NETCONF Server has determined - the temperature."; - } - - list additional-multi-lane-reporting { - when "(../identifier ='qsfp')or(../identifier ='qsfp+')"; - config false; - description - "Additional reporting according to SFF8436 which specifies real time - channel monitoring for each transmit and receive channel and includes - optical input power and Tx bias current. "; - key lane; - leaf lane { - type uint8 { - range "2..4"; - } - description - "the specific lane/channel associated with the report parameters"; - } - leaf rx-power { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured RX input power in mW. - - Optional node included when the NETCONF Server has determined - the measured RX power for a particular lane/channel - - see tabel 7-10 of SFF-8636."; - } - leaf tx-bias-current { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured transmitter laser bias current in mA. - - Optional node included when the NETCONF Server has determined - the tx bias current for a particular lane/channel - - see tabel 7-10 of SFF-8636."; - } - leaf tx-power { - type decimal64{ - fraction-digits 4; - } - config false; - description - "Measured coupled TX output power in mW. - - Optional node included when the NETCONF Server has determined - the measured coupled TX power or a particular lane/channel - - see tabel 7010 of SFF-8636."; - } - } - } - - } - - // Top Level Container - - container port-transceivers { - description - "Container for Port transceiver information. - Leaf nodes providing parameters status and diagnostic - information for pluggable transceiver module (like SFP, - SFP+, SFP28)"; - - uses transceiver-group; - } -} diff --git a/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang b/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang new file mode 120000 index 0000000..ca3e990 --- /dev/null +++ b/data-model/yang/published/o-ran/ru-fh/o-ran-transceiver.yang @@ -0,0 +1 @@ +./o-ran-transceiver@2022-12-05.yang \ No newline at end of file