X-Git-Url: https://gerrit.o-ran-sc.org/r/gitweb?a=blobdiff_plain;f=alarm%2Ftypes.go;h=ea6651ff5be2725e5b03b96088bd75a9bb1e7528;hb=54a3a4f89cf7de393be1ab28281a804e1b2c863e;hp=f3117f37b3dd6064d412b58945482dd665ba62e4;hpb=540ceee76d8653dd7cda456083452987cfd40321;p=ric-plt%2Falarm-go.git diff --git a/alarm/types.go b/alarm/types.go index f3117f3..ea6651f 100755 --- a/alarm/types.go +++ b/alarm/types.go @@ -67,11 +67,16 @@ type AlarmMessage struct { AlarmTime int64 } +type AlarmConfigParams struct { + MaxActiveAlarms int `json:"maxactivealarms"` + MaxAlarmHistory int `json:"maxalarmhistory"` +} + // RICAlarm is an alarm instance type RICAlarm struct { moId string appId string - adapterUrl string + managerUrl string rmrCtx unsafe.Pointer rmrReady bool mutex sync.Mutex @@ -88,43 +93,20 @@ const ( TCP_CONNECTIVITY_LOST_TO_DBAAS int = 8005 E2_CONNECTIVITY_LOST_TO_GNODEB int = 8006 E2_CONNECTIVITY_LOST_TO_ENODEB int = 8007 + ACTIVE_ALARM_EXCEED_MAX_THRESHOLD int = 8008 + ALARM_HISTORY_EXCEED_MAX_THRESHOLD int = 8009 ) type AlarmDefinition struct { - AlarmId int - AlarmText string - EventType string - OperationInstructions string + AlarmId int `json:"alarmid"` + AlarmText string `json:"alarmtext"` + EventType string `json:"eventtype"` + OperationInstructions string `json:"operationinstructions"` } -var RICAlarmDefinitions = map[int]AlarmDefinition{ - RIC_RT_DISTRIBUTION_FAILED: { - AlarmId: RIC_RT_DISTRIBUTION_FAILED, - AlarmText: "RIC ROUTING TABLE DISTRIBUTION FAILED", - EventType: "Processing error", - OperationInstructions: "Not defined", - }, - TCP_CONNECTIVITY_LOST_TO_DBAAS: { - AlarmId: TCP_CONNECTIVITY_LOST_TO_DBAAS, - AlarmText: "TCP CONNECTIVITY LOST TO DBAAS", - EventType: "Communication error", - OperationInstructions: "Not defined", - }, - E2_CONNECTIVITY_LOST_TO_GNODEB: { - AlarmId: E2_CONNECTIVITY_LOST_TO_GNODEB, - AlarmText: "E2 CONNECTIVITY LOST TO G-NODEB", - EventType: "Communication error", - OperationInstructions: "Not defined", - }, - E2_CONNECTIVITY_LOST_TO_ENODEB: { - AlarmId: E2_CONNECTIVITY_LOST_TO_ENODEB, - AlarmText: "E2 CONNECTIVITY LOST TO E-NODEB", - EventType: "Communication error", - OperationInstructions: "Not defined", - }, -} +var RICAlarmDefinitions map[int]*AlarmDefinition const ( - ALARM_ADAPTER_HTTP_URL string = "http://service-ricplt-alarmadapter-http.ricplt:8080" - ALARM_ADAPTER_RMR_URL string = "service-ricplt-alarmadapter-rmr.ricplt:4560" + ALARM_MANAGER_HTTP_URL string = "http://service-ricplt-alarmmanager-http.ricplt:8080" + ALARM_MANAGER_RMR_URL string = "service-ricplt-alarmmanager-rmr.ricplt:4560" )