meta-starlingx: remove the upstream layer
[pti/rtp.git] / meta-starlingx / meta-stx-cloud / recipes-support / puppet / files / stx-puppet / apply_network_config_poky.sh
diff --git a/meta-starlingx/meta-stx-cloud/recipes-support/puppet/files/stx-puppet/apply_network_config_poky.sh b/meta-starlingx/meta-stx-cloud/recipes-support/puppet/files/stx-puppet/apply_network_config_poky.sh
deleted file mode 100755 (executable)
index 8357378..0000000
+++ /dev/null
@@ -1,312 +0,0 @@
-#!/bin/bash
-
-################################################################################
-# Copyright (c) 2016 Wind River Systems, Inc.
-#
-# SPDX-License-Identifier: Apache-2.0
-#
-################################################################################
-
-#
-#  Purpose of this script is to copy the puppet-built
-#  network config file from the puppet dir to the /etc/network/interfaces  
-#  Only copied when difference detected 
-#
-#  Please note:  function is_eq_ifcfg() is used to determine if
-#                cfg files are different
-#
-
-ACQUIRE_LOCK=1
-RELEASE_LOCK=0
-
-if [ ! -f /var/run/interfaces.puppet ] ; then
-    # No puppet file? Nothing to do!
-    exit 1
-fi
-
-function log_it {
-    logger "${0} ${1}"
-}
-
-function do_if_up {
-    local iface=$1
-    log_it "Bringing $iface up"
-    /sbin/ifup $iface
-}
-
-function do_if_down {
-    local iface=$1
-    log_it "Bringing $iface down"
-    /sbin/ifdown $iface
-}
-
-function do_rm {
-    local theFile=$1
-    log_it "Removing $theFile"
-    /bin/rm  $theFile
-}
-
-function do_cp {
-    local srcFile=$1
-    local dstFile=$2
-    log_it "copying network cfg $srcFile to $dstFile"
-    cp  $srcFile $dstFile
-}
-
-function do_mv {
-    local srcFile=$1
-    local dstFile=$2
-    log_it "Moving network cfg $srcFile to $dstFile"
-    mv  $srcFile $dstFile
-}
-
-# Return items in list1 that are not in list2
-array_diff () {
-    list1=${!1}
-    list2=${!2}
-
-    result=()
-    l2=" ${list2[*]} "
-    for item in ${list1[@]}; do
-        if [[ ! $l2 =~ " $item " ]] ; then
-            result+=($item)
-        fi
-    done
-
-    echo  ${result[@]}
-}
-
-function normalized_cfg_attr_value {
-    local cfg=$1
-    local attr_name=$2
-    local attr_value
-    attr_value=$(cat $cfg | grep $attr_name= | awk -F "=" {'print $2'})
-
-
-    #
-    # Special case BONDING_OPTS attribute.
-    #
-    # The BONDING_OPTS attribute contains '=' characters, so is not correctly
-    # parsed by splitting on '=' as done above.  This results in changes to
-    # BONDING_OPTS not causing the interface to be restarted, so the old
-    # BONDING_OPTS still be used.  Because this is only checking for changes,
-    # rather than actually using the returned value, we can return the whole
-    # line.
-    #
-    if [[ "${attr_name}" == "BONDING_OPTS" ]]; then
-        echo "$(cat $cfg | grep $attr_name=)"
-        return $(true)
-    fi
-
-    if [[ "${attr_name}" != "BOOTPROTO" ]]; then
-        echo "${attr_value}"
-        return $(true)
-    fi
-    #
-    # Special case BOOTPROTO attribute.
-    #
-    # The BOOTPROTO attribute is not populated consistently by various aspects
-    # of the system.  Different values are used to indicate a manually
-    # configured interfaces (i.e., one that does not expect to have an IP
-    # address) and so to avoid reconfiguring an interface that has different
-    # values with the same meaning we normalize them here before making any
-    # decisions.
-    #
-    # From a user perspective the values "manual", "none", and "" all have the
-    # same meaning - an interface without an IP address while "dhcp" and
-    # "static" are distinct values with a separate meaning.  In practice
-    # however, the only value that matters from a ifup/ifdown script point of
-    # view is "dhcp".  All other values are ignored.
-    #
-    # In our system we set BOOTPROTO to "static" to indicate that IP address
-    # attributes exist and to "manual"/"none" to indicate that no IP address
-    # attributes exist.  These are not needed by ifup/ifdown as it looks for
-    # the "IPADDR" attribute whenever BOOTPROTO is set to anything other than
-    # "dhcp".
-    #
-    if [[ "${attr_value}" == "none" ]]; then
-        attr_value="none"
-    fi
-    if [[ "${attr_value}" == "manual" ]]; then
-        attr_value="none"
-    fi
-    if [[ "${attr_value}" == "" ]]; then
-        attr_value="none"
-    fi
-    echo "${attr_value}"
-    return $(true)
-}
-
-#
-# returns $(true) if cfg file ( $1 ) has property propName ( $2 ) with a value of propValue ( $3 )
-#
-function cfg_has_property_with_value {
-    local cfg=$1
-    local propname=$2
-    local propvalue=$3
-    if [ -f $cfg ]; then
-        if [[ "$(normalized_cfg_attr_value $cfg $propname)" == "${propvalue}" ]]; then
-            return $(true)
-        fi
-    fi
-    return $(false)
-}
-
-#
-# returns $(true) if cfg file is configured as a slave
-#
-function is_slave {
-    cfg_has_property_with_value $1 "SLAVE" "yes"
-    return $?
-}
-
-#
-# returns $(true) if cfg file is configured for DHCP
-#
-function is_dhcp {
-    cfg_has_property_with_value $1 "BOOTPROTO" "dhcp"
-}
-
-#
-# returns $(true) if cfg file is configured as a VLAN interface
-#
-function is_vlan {
-    cfg_has_property_with_value $1 "VLAN" "yes"
-    return $?
-}
-
-#
-# returns $(true) if cfg file is configured as an ethernet interface.  For the
-# purposes of this script "ethernet" is considered as any interface that is not
-# a vlan or a slave.  This includes both regular ethernet interfaces and bonded
-# interfaces.
-#
-function is_ethernet {
-    if ! is_vlan $1; then
-        if ! is_slave $1; then
-            return $(true)
-        fi
-    fi
-    return $(false)
-}
-
-#
-# returns $(true) if cfg file represents an interface of the specified type.
-#
-function iftype_filter {
-    local iftype=$1
-
-    return $(is_$iftype $2)
-}
-
-#
-# returns $(true) if ifcfg files have the same number of VFs
-#
-#
-function is_eq_sriov_numvfs {
-    local cfg_1=$1
-    local cfg_2=$2
-    local sriov_numvfs_1
-    sriov_numvfs_1=$(grep -o 'echo *[1-9].*sriov_numvfs' $cfg_1 | awk {'print $2'})
-    local sriov_numvfs_2
-    sriov_numvfs_2=$(grep -o 'echo *[1-9].*sriov_numvfs' $cfg_2 | awk {'print $2'})
-
-    sriov_numvfs_1=${sriov_numvfs_1:-0}
-    sriov_numvfs_2=${sriov_numvfs_2:-0}
-
-    if [[ "${sriov_numvfs_1}" != "${sriov_numvfs_2}" ]]; then
-        log_it "$cfg_1 and $cfg_2 differ on attribute sriov_numvfs [${sriov_numvfs_1}:${sriov_numvfs_2}]"
-        return $(false)
-    fi
-
-    return $(true)
-}
-
-#
-# returns $(true) if ifcfg files are equal
-#
-# Warning:  Only compares against cfg file attributes:
-#            BOOTPROTO DEVICE IPADDR NETMASK GATEWAY MTU BONDING_OPTS SRIOV_NUMVFS
-#
-function is_eq_ifcfg {
-    local cfg_1=$1
-    local cfg_2=$2
-
-    for attr in BOOTPROTO DEVICE IPADDR NETMASK GATEWAY MTU BONDING_OPTS; do
-        local attr_value1
-        attr_value1=$(normalized_cfg_attr_value $cfg_1 $attr)
-        local attr_value2
-        attr_value2=$(normalized_cfg_attr_value $cfg_2 $attr)
-        if [[ "${attr_value1}" != "${attr_value2}"  ]]; then
-            log_it "$cfg_1 and $cfg_2 differ on attribute $attr"
-            return $(false)
-        fi
-    done
-
-    is_eq_sriov_numvfs $1 $2
-    return $?
-}
-
-# Synchronize with sysinv-agent audit (ifup/down to query link speed).
-function sysinv_agent_lock {
-    case $1 in
-    $ACQUIRE_LOCK)
-        local lock_file="/var/run/apply_network_config.lock"
-        # Lock file should be the same as defined in sysinv agent code
-        local lock_timeout=5
-        local max=15
-        local n=1
-        LOCK_FD=0
-        exec {LOCK_FD}>$lock_file
-        while [[ $n -le $max ]]; do
-
-            flock -w $lock_timeout $LOCK_FD && break
-            log_it "Failed to get lock($LOCK_FD) after $lock_timeout seconds ($n/$max), will retry"
-            sleep 1
-            n=$(($n+1))
-        done
-        if [[ $n -gt $max ]]; then
-            log_it "Failed to acquire lock($LOCK_FD) even after $max retries"
-            exit 1
-        fi
-        ;;
-    $RELEASE_LOCK)
-        [[ $LOCK_FD -gt 0 ]] && flock -u $LOCK_FD
-        ;;
-    esac
-}
-
-
-# synchronize with sysinv-agent audit
-sysinv_agent_lock $ACQUIRE_LOCK
-
-# check if this is a duplicated configuration
-if ! diff -I '^#' "/var/run/interfaces.puppet" "/etc/network/interfaces" > /dev/null; then
-    # now copy the puppet changed interfaces to /etc/network/interfaces
-    do_mv /var/run/interfaces.puppet /etc/network/interfaces
-
-    # now restart networking service 
-    /etc/init.d/networking restart
-
-    sleep 5
-else
-    # need to remove this file also
-    do_rm /var/run/interfaces.puppet
-fi
-
-
-# workaround the loopback label addresses cannot be configured as scope of host
-ip addr show lo | egrep "inet.*global.*lo:" > /tmp/loop$$
-
-while read addr_info; do 
-       echo $addr_info
-       log_it "replace $addr_info with scope host"
-       addr=`echo $addr_info | cut -d' ' -f 2`
-       ifname=`echo $addr_info | cut -d' ' -f 5`
-       ip addr del $addr dev lo label $ifname
-       ip addr add $addr dev lo scope host label $ifname
-done < /tmp/loop$$
-
-
-# unlock: synchronize with sysinv-agent audit
-sysinv_agent_lock $RELEASE_LOCK