PNF Registration to be sent after odu stack is up
[o-du/l2.git] / docs / user-guide.rst
index eb5ccfc..3d6a845 100644 (file)
@@ -24,6 +24,9 @@ I. Execution - On locally compiling O-DU High Source Code
    b. ifconfig <interface name>:CU_STUB "192.168.130.82"
    c. ifconfig <interface name>:RIC_STUB "192.168.130.80"
 
+PS: If O1 interface is enabled, IPs should match those configured in "startup_config.xml"
+    ( Refer Installation Guide - "Setting up Netconf server" )
+
 2. Execute CU Stub:
 
    a. Navigate to CU execution folder
@@ -54,7 +57,7 @@ I. Execution - On locally compiling O-DU High Source Code
 
       - ./odu
 
-PS: CU stub and RIC stub must be run (in no particular sequence) before ODU
+PS: CU stub and RIC stub must be run (in no particular sequence) before ODU
 
 II. Execution - Using Docker Images
 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
@@ -193,10 +196,50 @@ Following diagram shows P5 messages exchanged with O-DU Low in timer mode.
 
 .. figure:: O-DU_High_Low_Flow.jpg
   :width: 600
-  :alt: Figure 1 O-DU High - O-DU Low Message Flow Diagram
+  :alt: Figure 7 O-DU High - O-DU Low Message Flow Diagram
 
-  Figure 5 - O-DU High - O-DU Low Message Flow Diagram
+  Figure 7 - O-DU High - O-DU Low Message Flow Diagram
 
 Note: UL IQ-Sample request and response are needed by Intel O-DU Low in timer mode(testing mode) only. Code changes for
 these are guarded under INTEL_TIMER_MODE flag which can be enabled using compilation option "PHY_MODE=TIMER", as
 mentioned in section B.I.1.d .
+
+
+D. Health Check execution: get alarm-list
+-------------------------------------------
+
+To execute the get alarm-list flow, following steps are required to be executed:
+
+   1.  Start Netconf netopeer client 
+   
+   2. Connect to the server with 
+
+      | user: netconf
+      | pwd:  netconf!
+
+   3. Send a Netconf get request for alarms xpath
+
+Here are the steps as executed in the terminal 
+
+     |  netopeer2-cli
+     |  > connect --login netconf
+     |  Interactive SSH Authentication
+     |  Type your password:
+     |  Password:
+     |  > get --filter-xpath /o-ran-sc-odu-alarm-v1\:odu/alarms
+     |  DATA
+     |  <odu xmlns=\"urn\:o-ran\:odu\:alarm\:1.0\">
+     |    <alarms>
+     |      <alarm>
+     |        <alarm-id>1009</alarm-id>
+     |        <alarm-text>cell id  [1] is up</alarm-text>
+     |        <severity>2</severity>
+     |        <status>Active</status>
+     |        <additional-info>cell UP</additional-info>
+     |      </alarm>
+     |    </alarms>
+     |  </odu>
+
+The XML output is a list of active alarms in the O-DU High system.
+
+Note: Integration with SMO/OAM is not yet done so a Netconf CLI client(netopeer2-cli) is used to connect to the Netconf server and send the get request.