--atx Alarm text string, example string: E2 CONNECTIVITY LOST TO E-NODEB
--ety Event type string, example string: Communication error
--oin Operation instructions string, example string: Not defined
+ --rad Raise alarm delay in seconds. Default value = 0
+ --cad Clear alarm delay in seconds. Default value = 0
--prf Performance profile id, possible values: 1 = peak performance test or 2 = endurance test
--nal Number of alarms, example value: 50
--aps Alarms per second, example value: 1
.. code-block:: none
- Syntax: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" [--host] [--port]
+ Syntax: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" [--rad] [--cad] [--host] [--port]
- Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined"
+ Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --rad 0 --cad 0
- Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --host localhost --port 8080
+ Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --rad 0 --cad 0 --host localhost --port 8080
Delete existing alarm definition:
Add one new alarm definition:
- Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\"}]}"
+ Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\, \"raiseDelay\": 1, \"clearDelay\": 1"}]}"
Add two new alarm definitions:
- Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\"},{\"alarmId\": 8008, \"alarmText\": \"ACTIVE ALARM EXCEED MAX THRESHOLD\", \"eventtype\": \"storage warning\", \"operationinstructions\": \"Clear alarms or raise threshold\"}]}"
+ Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\, \"raiseDelay\": 0, \"clearDelay\": 0"},{\"alarmId\": 8008, \"alarmText\": \"ACTIVE ALARM EXCEED MAX THRESHOLD\", \"eventtype\": \"storage warning\", \"operationinstructions\": \"Clear alarms or raise threshold\", \"raiseDelay\": 0, \"clearDelay\": 0}]}"