--- /dev/null
+.. This work is licensed under a Creative Commons Attribution 4.0 International License.\r
+.. SPDX-License-Identifier: CC-BY-4.0\r
+.. Copyright (C) 2020 CommScope Inc.\r
+\r
+TR-069 Adapter User Guide\r
+=========================\r
+\r
+This document provides a quick start for using TR-069 Adapter.\r
+\r
+\r
+TR-069 Device Connecting to TR-069 Adapter\r
+------------------------------------------\r
+\r
+Configure URL **http://<external_address_tr-069Adapter>/CPEMgmt/acs** to Device as Management Server URL. \r
+\r
+Importing a Initial PnP Configuration file\r
+------------------------------------------\r
+Initial PnP Configuration file supports the ability to configure the PnP parameters that TR-069Adapter must provision to the Device as part of a BootStrap Inform. The configuration XML (3GPP TS 32.594) file is used to define the initial PnP Configurations for Device. Before importing a configuration file to a server you must edit the file to enter the required configuration details.\r
+\r
+To import a configuration file:\r
+\r
+1. Access the sample configuration file (samplexmls/macid.xml) from the distribution package.\r
+\r
+2. Edit the macid string in macid.xml file with the device’s macid value.\r
+\r
+3. Edit the file to add the device configuration details, in the same format as mentioned in the sample file.\r
+\r
+4. To import initial PnP configuration file using curl use following command \r
+\r
+ ``$curl -F 'files=@<completeFilePath>' http://<external_address>/importConfig``\r
+\r
+ For example:\r
+ ``$curl -F 'files=@/home/tr069admin/0005b9423910.xml' http://tr069.amazonaws.com/importConfig``\r
+\r
+5. You can check the imported configuration file details by entering the config service IP, external port, getConfig command, and MACID as shown in the below format in your browser:\r
+\r
+ ``http://<config_service_IP>:<external_port>/<getConfig>/<MAC_ID>`` \r
+\r
+ For example, ``http://tr069.amazonaws.com/getConfig/0005B9423910`` \r
+\r
+\r
+Mounting a Device in SDN-R\r
+--------------------------\r
+\r
+Device will get auto mounted in SDN-R once the BootStrap message is received from device and forwarded to VES Collector as VES PnfRegistration message by TR-069 Adapter. \r