+D. Push cell and slice configuration over O1 using netopeer-cli
+---------------------------------------------------------------
+ When O-DU High is run with O1 enabled it waits for initial cell configuration to be pushed by SMO before starting the stack. In case the SMO is not available then these configurations can be pushed via netopeer-cli as follows:
+
+ | $cd l2/build/config
+ | $netopeer2-cli
+ | > connect --login netconf
+ | Interactive SSH Authentication
+ | Type your password:
+ | Password: netconf!
+ | > edit-config --target candidate --config=cellConfig.xml
+ | > OK
+ | > commit
+ | > OK
+ | > edit-config --target candidate --config=rrmPolicy.xml
+ | > OK
+ | > commit
+ | > OK
+
+ For pushing these configurations in subsequent runs please edit cellConfig.xml and rrmPolicy.xml and increment number in the <id> tag to a new value e.g.
+
+ <id>rrm-2</id
+
+E. How to execute the Health Check using netopeer-cli : get alarm-list
+-----------------------------------------------------------------------
+
+ In case the SMO is not available the alarm list can be checked using netopeer-cli as follows:
+
+ | netopeer2-cli
+ | > connect --login netconf
+ | Interactive SSH Authentication
+ | Type your password:
+ | Password: netconf!
+ | > get --filter-xpath /o-ran-sc-odu-alarm-v1\:odu/alarms
+ | DATA
+ | <odu xmlns=\"urn\:o-ran\:odu\:alarm\:1.0\">
+ | <alarms>
+ | <alarm>
+ | <alarm-id>1009</alarm-id>
+ | <alarm-text>cell id [1] is up</alarm-text>
+ | <severity>2</severity>
+ | <status>Active</status>
+ | <additional-info>cell UP</additional-info>
+ | </alarm>
+ | </alarms>
+ | </odu>
+
+The XML output is a list of active alarms in the O-DU High system.
+