-The alarm feature sends messages using RMR message type
-`RIC_ALARM_UPDATE` in the `ricxappframe.alarm.alarm` module, currently
-value 13111. The Xapp's routing table must have one (or more) entries
-for that message type.
+The alarm feature opens a direct connection to the alarm manager
+using the RMR library's wormhole feature, taking the host name and
+port number from environment variables defined as the constants
+`ALARM_MGR_SERVICE_NAME_ENV` and `ALARM_MGR_SERVICE_PORT_ENV` in
+the `ricxappframe.alarm.alarm` module. The message type is set to
+constant `RIC_ALARM_UPDATE` in the `ricxappframe.alarm.alarm` module,
+currently 110.