+H. How to execute the Health Check : get alarm-list
+----------------------------------------------------
+
+ Steps:
+
+ 1. Start Netconf netopeer client
+
+ 2. Connect to the server with
+
+ user: netconf
+ pwd: netconf!
+
+ 3. Send a Netconf get request for alarms xpath
+
+ Here are the steps as executed in the terminal
+
+ $netopeer2-cli
+ > connect --login netconf
+ Interactive SSH Authentication
+ Type your password:
+ Password:
+ > get --filter-xpath /o-ran-sc-odu-alarm-v1:odu/alarms
+ DATA
+ <odu xmlns="urn:o-ran:odu:alarm:1.0">
+ <alarms>
+ <alarm>
+ <alarm-id>1009</alarm-id>
+ <alarm-text>cell id [1] is up</alarm-text>
+ <severity>2</severity>
+ <status>Active</status>
+ <additional-info>cell UP</additional-info>
+ </alarm>
+ </alarms>
+ </odu>
+
+ The XML output is a list of active alarms in the O-DU High system.
+
+
+G. Troubleshooting Netconf server issues
+----------------------------------------
+ In case the Netconf server and sysrepo breaks down, run the following steps:
+
+ $cd l2/build/scripts
+ $sudo ./troubleshoot_netconf.sh cleanup
+ execute section C.2.f, C.3 again