LN0739_FM_RF13: support interface to external Prometheus alert manager
[ric-plt/alarm-go.git] / docs / user-guide.rst
1 ..
2 ..  Copyright (c) 2019 AT&T Intellectual Property.
3 ..  Copyright (c) 2019 Nokia.
4 ..
5 ..  Licensed under the Creative Commons Attribution 4.0 International
6 ..  Public License (the "License"); you may not use this file except
7 ..  in compliance with the License. You may obtain a copy of the License at
8 ..
9 ..    https://creativecommons.org/licenses/by/4.0/
10 ..
11 ..  Unless required by applicable law or agreed to in writing, documentation
12 ..  distributed under the License is distributed on an "AS IS" BASIS,
13 ..  WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 ..
15 ..  See the License for the specific language governing permissions and
16 ..  limitations under the License.
17 ..
18
19 User-Guide
20 ==========
21
22 .. contents::
23    :depth: 3
24    :local:
25
26 RIC Alarm System
27 ----------------
28
29 Overview
30 --------
31 RIC alarm system consists of three components: Alarm Manager, Application Library and Command Line Interface
32
33 The Alarm Manager is responsible for managing alarm situations in RIC cluster and interfacing with Northbound applications
34 such as Prometheus Alert Manager to post the alarms as alerts. Alert Manager takes care of de-duplicating, silencing and
35 inhibition (suppressing) of alerts, and routing them to the VES-Agent, which, in turn, takes care of converting alerts to
36 faults and sending them to ONAP as VES events.
37
38 The Alarm Library provides a simple interface for RIC applications (both platform application and xApps) to raise and clear
39 alarms. The Alarm Library interacts with the Alarm Manager via RMR interface.
40
41     .. image:: images/RIC_Alarm_System.png
42       :width: 600
43       :alt: Place in RIC's software architecture picture
44
45
46 Alarm Manager
47 -------------
48 The Alarm Manager listens alarms coming via RMR and REST interfaces. An application can raise or clear alarms via either
49 of interfaces. Alarm Manager listens also commands coming from CLI (Command Line Interface). In addition Alarm Manager supports few
50 other commands that can be given through the interfaces. Such as list active alarms, list alarm history, add new alarms
51 definition, delete existing alarm definition, re-raise alarms and clear all alarms. Those are not typically used by applications while
52 running. Alarm Manager itself re-raises alarms periodically to keep alarms in active state. The other commands are can be used through
53 CLI interface by operator or are used when applications is starting up or restarting.
54
55 Maximum amount of active alarms and size of alarm history are configurable. By default, the values are Maximum number of active
56 alarms = 5000, Maximum number of alarm history = 20,000.
57
58 Alarm definitions can be updated dynamically via REST interface. Default definitions are read from JSON configuration file when FM
59 service is deployed.
60
61
62 Alarm Library
63 -------------
64 The Alarm Library provides simple interface for RIC applications (both platform application and xApps) to raise and clear
65 alarms. A new alarm instance is created with InitAlarm()-function. ManagedObject (mo) and Application (ap) identities are
66 given as parameters for Alarm Context/Object
67
68 The Alarm object contains following parameters:
69
70     SpecificProblem: problem that is the cause of the alarm \(*
71
72     PerceivedSeverity: The severity of the alarm, see below for possible values
73
74     ManagedObjectId: The name of the managed object that is the cause of the fault \(*
75
76     ApplicationId: The name of the process raised the alarm \(*
77
78     AdditionalInfo: Additional information given by the application
79
80     IdentifyingInfo: Identifying additional information, which is part of alarm identity \(*
81
82 Items marked with \*, i.e., ManagedObjectId (mo), SpecificProblem (sp), ApplicationId (ap) and IdentifyingInfo (IdentifyingInfo) make
83 up the identity of the alarm. All parameters must be according to the alarm definition, i.e. all mandatory parameters should be present,
84 and parameters should have correct value type or be from some predefined range. Addressing the same alarm instance in a clear() or reraise()
85 call is done by making sure that all four values are the same is in the original raise() / reraise() call.
86
87 Alarm Manager does not allow raising "same alarm" more than once without that the alarm is cleared first. Alarm Manager compares
88 ManagedObjectId (mo), SpecificProblem (sp), ApplicationId (ap) and IdentifyingInfo (IdentifyingInfo) parameters to check possible 
89 duplicate. If the values are the same then alarm is suppressed. If application raises the "same alarm" but PerceivedSeverity of the alarm
90 is changed then Alarm Manager deletes the old alarm and makes new alarm according to new information.
91
92
93 Alarm APIs
94
95     Raise: Raises the alarm instance given as a parameter
96
97     Clear: Clears the alarm instance given as a parameter, if it the alarm active
98
99     Reraise: Attempts to re-raise the alarm instance given as a parameter
100
101     ClearAll: Clears all alarms matching moId and appId given as parameters (not supported yet)
102
103
104 Command line interface
105 ----------------------
106
107 Through CLI operator can do the following operations:
108
109  - Check active alarms
110  - Check alarm history
111  - Raise an alarm
112  - Clear an alarm
113  - Configure maximum active alarms and maximum alarms in alarm history
114  - Add new alarm definitions that can be raised
115  - Delete existing alarm definition that can be raised
116
117 CLI commands need to be given inside Alarm Manger pod. To get there first print name of the Alarm Manger pod.
118
119 .. code-block:: none
120
121  kubectl get pods -A | grep alarmmanager
122
123 Output should be look someting like this: 
124
125 .. code-block:: none
126
127  ricplt  deployment-ricplt-alarmmanager-6cc8764749-gnwjh 1/1 running 0  15d
128
129 Then give this command to enter inside the pod. Replace the pod name with the actual name from the printout.
130
131 .. code-block:: none
132
133  kubectl exec -it deployment-ricplt-alarmmanager-6cc8764749-gnwjh bash
134
135 CLI commands can have some of the following parameters
136
137 .. code-block:: none
138
139  --moid        ManagedObjectId, example string: RIC 
140  --apid        ApplicationId string, example string: UEEC  
141  --sp          SpecificProblem, example value: 8007
142  --severity    Severity of the alarm, possible values: UNSPECIFIED, CRITICAL, MAJOR, MINOR, WARNING, CLEARED or DEFAULT
143  --iinfo       Identifying info, a user specified string, example string: INFO-1
144  --mal         Maximum number of active alarms, example value 1000
145  --mah         Maximum number of alarms in alarm history, example value: 2000
146  --aid         Alarm id, example value: 8007
147  --atx         Alarm text string, example string: E2 CONNECTIVITY LOST TO E-NODEB
148  --ety         Event type string, example string: Communication error
149  --oin         Operation instructions string, example string: Not defined
150  --prf         Performance profile id, possible values: 1 = peak performance test or 2 = endurance test
151  --nal         Number of alarms, example value: 50
152  --aps         Alarms per second, example value: 1
153  --tim         Total time of test in minutes, example value: 1 
154  --host        Alarm Manager host address. Default value = localhost
155  --port        Alarm Manager port. Default value = 8080
156  --if          Used Alarm Manager command interface, http or rmr: default value = http
157  --active      Active alerts in Prometheus Alert Manager. Default value = true
158  --inhibited   Inhibited alerts in Prometheus Alert Manager. Default value = true
159  --silenced    Silenced alerts in Prometheus Alert Manager. Default value = true
160  --unprocessed Unprocessed alerts in Prometheus Alert Manager. Default value = true
161  --host        Prometheus Alert Manager host address
162  --port        Prometheus Alert Manager port. Default value = 9093
163
164
165 ``Note that there are two minus signs before parameter name!``
166  
167 If parameter contains any white spaces then it must be enclosed in quotation marks like: "INFO 1"
168
169 CLI command examples:
170
171  Following command are given at top level directory!
172
173  Check active alarms:
174
175  .. code-block:: none
176
177   Syntax: cli/alarm-cli active [--host] [--port]
178    
179   Example: cli/alarm-cli active
180
181   Example: cli/alarm-cli active --host localhost --port 8080
182
183  Check alarm history:
184
185  .. code-block:: none
186
187   Syntax: cli/alarm-cli active  [--host] [--port]
188
189   Example: cli/alarm-cli history
190
191   Example: cli/alarm-cli history --host localhost --port 8080
192
193  Raise alarm:
194
195  .. code-block:: none
196
197   Syntax: cli/alarm-cli raise --moid --apid --sp --severity --iinfo [--host] [--port] [--if]
198
199   Example: cli/alarm-cli raise --moid RIC --apid UEEC --sp 8007 --severity CRITICAL --iinfo INFO-1
200
201   Following is meant only for testing and verification purpose!
202
203   Example: cli/alarm-cli raise --moid RIC --apid UEEC --sp 8007 --severity CRITICAL --iinfo INFO-1 --host localhost --port 8080 --if rmr
204
205  Clear alarm:
206
207  .. code-block:: none
208
209   Syntax: cli/alarm-cli clear --moid --apid --sp --severity --iinfo [--host] [--port] [--if]
210
211   Example: cli/alarm-cli clear --moid RIC --apid UEEC --sp 8007 --iinfo INFO-1
212
213   Example: cli/alarm-cli clear --moid RIC --apid UEEC --sp 8007 --iinfo INFO-1 --host localhost --port 8080 --if rmr
214
215  Configure maximum active alarms and maximum alarms in alarm history:
216
217  .. code-block:: none
218
219   Syntax: cli/alarm-cli configure --mal --mah [--host] [--port]
220
221   Example: cli/alarm-cli configure --mal 1000 --mah 5000
222
223   Example: cli/alarm-cli configure --mal 1000 --mah 5000 --host localhost --port 8080
224
225  Add new alarm definition:
226
227  .. code-block:: none
228
229   Syntax: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" [--host] [--port]
230
231   Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined"
232
233   Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --host localhost --port 8080
234
235  Delete existing alarm definition:
236
237  .. code-block:: none
238
239   Syntax: cli/alarm-cli undefine --aid [--host] [--port]
240
241   Example: cli/alarm-cli undefine --aid 8007
242
243   Example: cli/alarm-cli undefine --aid 8007 --host localhost --port 8080
244
245  Conduct performance test:
246
247  Note that this is meant only for testing and verification purpose!
248
249  Before any performance test command can be issued, an environment variable needs to be set. The variable holds information where
250  test alarm object file is stored.
251
252  .. code-block:: none
253
254   PERF_OBJ_FILE=cli/perf-alarm-object.json
255
256   Syntax: cli/alarm-cli perf --prf --nal --aps --tim [--host] [--port] [--if]
257
258   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --if rmr
259
260   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --if http
261
262   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --host localhost --port 8080 --if rmr
263
264   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --if rmr
265
266   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --if http
267
268   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --host localhost --port 8080 --if rmr
269
270 Get alerts from Prometheus Alert Manager: 
271
272  .. code-block:: none
273
274   Syntax: cli/alarm-cli gapam --active --inhibited --silenced --unprocessed --host [--port]
275
276   Example: cli/alarm-cli gapam --active true --inhibited true --silenced true --unprocessed true --host 10.102.36.121 --port 9093
277
278
279 REST interface usage guide
280 --------------------------
281
282 REST interface offers all the same services plus some more that are available via CLI. The CLI also uses the REST interface to implement the services it offers.
283
284 Below are examples for REST interface. Curl tool is used to send REST commands.
285
286  Check active alarms:
287
288    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/active" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
289
290  Check alarm history:
291
292    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/history" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
293
294  Raise alarm:
295
296    Example: curl -X POST "http://localhost:8080/ric/v1/alarms" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"managedObjectId\": \"RIC\", \"applicationId\": \"UEEC\", \"specificProblem\": 8007, \"perceivedSeverity\": \"CRITICAL\", \"additionalInfo\": \"-\", \"identifyingInfo\": \"INFO-1\", \"AlarmAction\": \"RAISE\", \"AlarmTime\": 0}"
297
298  Clear alarm:
299
300    Example: curl -X DELETE "http://localhost:8080/ric/v1/alarms" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"managedObjectId\": \"RIC\", \"applicationId\": \"UEEC\", \"specificProblem\": 8007, \"perceivedSeverity\": \"\", \"additionalInfo\": \"-\", \"identifyingInfo\": \"INFO-1\", \"AlarmAction\": \"CLEAR\", \"AlarmTime\": 0}"
301
302  Get configuration of maximum active alarms and maximum alarms in alarm history:
303
304    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/config" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
305
306  Configure maximum active alarms and maximum alarms in alarm history:
307
308    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/config" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"maxactivealarms\": 1000, \"maxalarmhistory\": 5000}"
309
310  Get all alarm definitions:
311
312    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
313
314  Get an alarm definition:
315
316    Syntax: curl -X GET "http://localhost:8080/ric/v1/alarms/define/{alarmId}" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
317
318    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/define/8007" -H  "accept: application/json" -H "Content-Type: application/json" -d "{}"
319
320  Add one new alarm definition:
321
322    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\"}]}"
323
324  Add two new alarm definitions:
325
326    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\"},{\"alarmId\": 8008, \"alarmText\": \"ACTIVE ALARM EXCEED MAX THRESHOLD\", \"eventtype\": \"storage warning\", \"operationinstructions\": \"Clear alarms or raise threshold\"}]}"
327
328  Delete one existing alarm definition:
329
330    Syntax: curl -X DELETE "http://localhost:8080/ric/v1/alarms/define/{alarmId}" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
331
332    Example: curl -X DELETE "http://localhost:8080/ric/v1/alarms/define/8007" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
333
334
335 RMR interface usage guide
336 -------------------------
337 Through RMR interface application can only raise and clear alarms. RMR message payload is similar JSON message as in above REST interface use cases.
338
339  Supported events via RMR interface
340   
341   - Raise alarm
342   - Clear alarm
343   - Reraise alarm
344   - ClearAll alarms (not supported yet)
345
346
347 Example on how to use the API from Golang code
348 ----------------------------------------------
349 Alarm library functions can be used directly from Golang code. Rising and clearing alarms goes via RMR interface from alarm library to Alarm Manager.
350
351
352 .. code-block:: none
353
354  package main
355
356  import (
357     alarm "gerrit.o-ran-sc.org/r/ric-plt/alarm-go/alarm"
358  )
359
360  func main() {
361     // Initialize the alarm component
362     alarmer, err := alarm.InitAlarm("my-pod", "my-app")
363
364     // Create a new Alarm object (SP=8004, etc)
365     alarm := alarmer.NewAlarm(8004, alarm.SeverityMajor, "NetworkDown", "eth0")
366
367     // Raise an alarm (SP=8004, etc)
368     err := alarmer.Raise(alarm)
369
370     // Clear an alarm (SP=8004)
371     err := alarmer.Clear(alarm)
372
373     // Re-raise an alarm (SP=8004)
374     err := alarmer.Reraise(alarm)
375
376     // Clear all alarms raised by the application - (not supported yet)
377     err := alarmer.ClearAll()
378  }
379  
380  
381 Example VES event
382 -----------------
383
384 .. code-block:: none
385
386  INFO[2020-06-08T07:50:10Z]
387  {
388    "event": {
389      "commonEventHeader": {
390        "domain": "fault",
391        "eventId": "fault0000000001",
392        "eventName": "Fault_ricp_E2 CONNECTIVITY LOST TO G-NODEB",
393        "lastEpochMicrosec": 1591602610944553,
394        "nfNamingCode": "ricp",
395        "priority": "Medium",
396        "reportingEntityId": "035EEB88-7BA2-4C23-A349-3B6696F0E2C4",
397        "reportingEntityName": "Vespa",
398        "sequence": 1,
399        "sourceName": "RIC",
400        "startEpochMicrosec": 1591602610944553,
401        "version": 3
402      },
403
404      "faultFields": {
405        "alarmCondition": "E2 CONNECTIVITY LOST TO G-NODEB",
406        "eventSeverity": "MAJOR",
407        "eventSourceType": "virtualMachine",
408        "faultFieldsVersion": 2,
409        "specificProblem": "eth12",
410        "vfStatus": "Active"
411      }
412    }