Updating RMR version to 4.5.2
[ric-plt/alarm-go.git] / docs / user-guide.rst
1 ..
2 ..  Copyright (c) 2019 AT&T Intellectual Property.
3 ..  Copyright (c) 2019 Nokia.
4 ..
5 ..  Licensed under the Creative Commons Attribution 4.0 International
6 ..  Public License (the "License"); you may not use this file except
7 ..  in compliance with the License. You may obtain a copy of the License at
8 ..
9 ..    https://creativecommons.org/licenses/by/4.0/
10 ..
11 ..  Unless required by applicable law or agreed to in writing, documentation
12 ..  distributed under the License is distributed on an "AS IS" BASIS,
13 ..  WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 ..
15 ..  See the License for the specific language governing permissions and
16 ..  limitations under the License.
17 ..
18
19 User-Guide
20 ==========
21
22 .. contents::
23    :depth: 3
24    :local:
25
26 RIC Alarm System
27 ----------------
28
29 Overview
30 --------
31 RIC alarm system consists of three components: Alarm Manager, Application Library and Command Line Interface
32
33 The Alarm Manager is responsible for managing alarm situations in RIC cluster and interfacing with Northbound applications
34 such as Prometheus Alert Manager to post the alarms as alerts. Alert Manager takes care of de-duplicating, silencing and
35 inhibition (suppressing) of alerts, and routing them to the VES-Agent, which, in turn, takes care of converting alerts to
36 faults and sending them to ONAP as VES events.
37
38 The Alarm Library provides a simple interface for RIC applications (both platform application and xApps) to raise and clear
39 alarms. The Alarm Library interacts with the Alarm Manager via RMR interface.
40
41     .. image:: images/RIC_Alarm_System.png
42       :width: 600
43       :alt: Place in RIC's software architecture picture
44
45
46 Alarm Manager
47 -------------
48 The Alarm Manager listens alarms coming via RMR and REST interfaces. An application can raise or clear alarms via either
49 of interfaces. Alarm Manager listens also commands coming from CLI (Command Line Interface). In addition Alarm Manager supports few
50 other commands that can be given through the interfaces. Such as list active alarms, list alarm history, add new alarms
51 definition, delete existing alarm definition, re-raise alarms and clear all alarms. Those are not typically used by applications while
52 running. Alarm Manager itself re-raises alarms periodically to keep alarms in active state. The other commands are can be used through
53 CLI interface by operator or are used when applications is starting up or restarting.
54
55 Maximum amount of active alarms and size of alarm history are configurable. By default, the values are Maximum number of active
56 alarms = 5000, Maximum number of alarm history = 20,000.
57
58 Alarm definitions can be updated dynamically via REST interface. Default definitions are read from JSON configuration file when FM
59 service is deployed.
60
61
62 Alarm Library
63 -------------
64 The Alarm Library provides simple interface for RIC applications (both platform application and xApps) to raise and clear
65 alarms. A new alarm instance is created with InitAlarm()-function. ManagedObject (mo) and Application (ap) identities are
66 given as parameters for Alarm Context/Object
67
68 The Alarm object contains following parameters:
69
70     SpecificProblem: problem that is the cause of the alarm \(*
71
72     PerceivedSeverity: The severity of the alarm, see below for possible values
73
74     ManagedObjectId: The name of the managed object that is the cause of the fault \(*
75
76     ApplicationId: The name of the process raised the alarm \(*
77
78     AdditionalInfo: Additional information given by the application
79
80     IdentifyingInfo: Identifying additional information, which is part of alarm identity \(*
81
82 Items marked with \*, i.e., ManagedObjectId (mo), SpecificProblem (sp), ApplicationId (ap) and IdentifyingInfo (IdentifyingInfo) make
83 up the identity of the alarm. All parameters must be according to the alarm definition, i.e. all mandatory parameters should be present,
84 and parameters should have correct value type or be from some predefined range. Addressing the same alarm instance in a clear() or reraise()
85 call is done by making sure that all four values are the same is in the original raise() / reraise() call.
86
87 Alarm Manager does not allow raising "same alarm" more than once without that the alarm is cleared first. Alarm Manager compares
88 ManagedObjectId (mo), SpecificProblem (sp), ApplicationId (ap) and IdentifyingInfo (IdentifyingInfo) parameters to check possible 
89 duplicate. If the values are the same then alarm is suppressed. If application raises the "same alarm" but PerceivedSeverity of the alarm
90 is changed then Alarm Manager deletes the old alarm and makes new alarm according to new information.
91
92
93 Alarm APIs
94
95     Raise: Raises the alarm instance given as a parameter
96
97     Clear: Clears the alarm instance given as a parameter, if it the alarm active
98
99     Reraise: Attempts to re-raise the alarm instance given as a parameter
100
101     ClearAll: Clears all alarms matching moId and appId given as parameters (not supported yet)
102
103
104 Command line interface
105 ----------------------
106
107 Through CLI operator can do the following operations:
108
109  - Check active alarms
110  - Check alarm history
111  - Raise an alarm
112  - Clear an alarm
113  - Configure maximum active alarms and maximum alarms in alarm history
114  - Add new alarm definitions that can be raised
115  - Delete existing alarm definition that can be raised
116
117 CLI commands need to be given inside Alarm Manger pod. To get there first print name of the Alarm Manger pod.
118
119 .. code-block:: none
120
121  kubectl get pods -A | grep alarmmanager
122
123 Output should be look someting like this: 
124
125 .. code-block:: none
126
127  ricplt  deployment-ricplt-alarmmanager-6cc8764749-gnwjh 1/1 running 0  15d
128
129 Then give this command to enter inside the pod. Replace the pod name with the actual name from the printout.
130
131 .. code-block:: none
132
133  kubectl exec -it deployment-ricplt-alarmmanager-6cc8764749-gnwjh bash
134
135 CLI commands can have some of the following parameters
136
137 .. code-block:: none
138
139  --moid        ManagedObjectId, example string: RIC 
140  --apid        ApplicationId string, example string: UEEC  
141  --sp          SpecificProblem, example value: 8007
142  --severity    Severity of the alarm, possible values: UNSPECIFIED, CRITICAL, MAJOR, MINOR, WARNING, CLEARED or DEFAULT
143  --iinfo       Identifying info, a user specified string, example string: INFO-1
144  --mal         Maximum number of active alarms, example value 1000
145  --mah         Maximum number of alarms in alarm history, example value: 2000
146  --aid         Alarm id, example value: 8007
147  --atx         Alarm text string, example string: E2 CONNECTIVITY LOST TO E-NODEB
148  --ety         Event type string, example string: Communication error
149  --oin         Operation instructions string, example string: Not defined
150  --rad         Raise alarm delay in seconds. Default value = 0
151  --cad         Clear alarm delay in seconds. Default value = 0
152  --prf         Performance profile id, possible values: 1 = peak performance test or 2 = endurance test
153  --nal         Number of alarms, example value: 50
154  --aps         Alarms per second, example value: 1
155  --tim         Total time of test in minutes, example value: 1 
156  --host        Alarm Manager host address. Default value = localhost
157  --port        Alarm Manager port. Default value = 8080
158  --if          Used Alarm Manager command interface, http or rmr: default value = http
159  --active      Active alerts in Prometheus Alert Manager. Default value = true
160  --inhibited   Inhibited alerts in Prometheus Alert Manager. Default value = true
161  --silenced    Silenced alerts in Prometheus Alert Manager. Default value = true
162  --unprocessed Unprocessed alerts in Prometheus Alert Manager. Default value = true
163  --host        Prometheus Alert Manager host address
164  --port        Prometheus Alert Manager port. Default value = 9093
165
166
167 ``Note that there are two minus signs before parameter name!``
168  
169 If parameter contains any white spaces then it must be enclosed in quotation marks like: "INFO 1"
170
171 CLI command examples:
172
173  Following command are given at top level directory!
174
175  Check active alarms:
176
177  .. code-block:: none
178
179   Syntax: cli/alarm-cli active [--host] [--port]
180    
181   Example: cli/alarm-cli active
182
183   Example: cli/alarm-cli active --host localhost --port 8080
184
185  Check alarm history:
186
187  .. code-block:: none
188
189   Syntax: cli/alarm-cli active  [--host] [--port]
190
191   Example: cli/alarm-cli history
192
193   Example: cli/alarm-cli history --host localhost --port 8080
194
195  Raise alarm:
196
197  .. code-block:: none
198
199   Syntax: cli/alarm-cli raise --moid --apid --sp --severity --iinfo [--host] [--port] [--if]
200
201   Example: cli/alarm-cli raise --moid RIC --apid UEEC --sp 8007 --severity CRITICAL --iinfo INFO-1
202
203   Following is meant only for testing and verification purpose!
204
205   Example: cli/alarm-cli raise --moid RIC --apid UEEC --sp 8007 --severity CRITICAL --iinfo INFO-1 --host localhost --port 8080 --if rmr
206
207  Clear alarm:
208
209  .. code-block:: none
210
211   Syntax: cli/alarm-cli clear --moid --apid --sp --severity --iinfo [--host] [--port] [--if]
212
213   Example: cli/alarm-cli clear --moid RIC --apid UEEC --sp 8007 --iinfo INFO-1
214
215   Example: cli/alarm-cli clear --moid RIC --apid UEEC --sp 8007 --iinfo INFO-1 --host localhost --port 8080 --if rmr
216
217  Configure maximum active alarms and maximum alarms in alarm history:
218
219  .. code-block:: none
220
221   Syntax: cli/alarm-cli configure --mal --mah [--host] [--port]
222
223   Example: cli/alarm-cli configure --mal 1000 --mah 5000
224
225   Example: cli/alarm-cli configure --mal 1000 --mah 5000 --host localhost --port 8080
226
227  Add new alarm definition:
228
229  .. code-block:: none
230
231   Syntax: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" [--rad] [--cad] [--host] [--port]
232
233   Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --rad 0 --cad 0
234
235   Example: cli/alarm-cli define --aid 8007 --atx "E2 CONNECTIVITY LOST TO E-NODEB" --ety "Communication error" --oin "Not defined" --rad 0 --cad 0 --host localhost --port 8080
236
237  Delete existing alarm definition:
238
239  .. code-block:: none
240
241   Syntax: cli/alarm-cli undefine --aid [--host] [--port]
242
243   Example: cli/alarm-cli undefine --aid 8007
244
245   Example: cli/alarm-cli undefine --aid 8007 --host localhost --port 8080
246
247  Conduct performance test:
248
249  Note that this is meant only for testing and verification purpose!
250
251  Before any performance test command can be issued, an environment variable needs to be set. The variable holds information where
252  test alarm object file is stored.
253
254  .. code-block:: none
255
256   PERF_OBJ_FILE=cli/perf-alarm-object.json
257
258   Syntax: cli/alarm-cli perf --prf --nal --aps --tim [--host] [--port] [--if]
259
260   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --if rmr
261
262   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --if http
263
264   Peak performance test example: cli/alarm-cli perf --prf 1 --nal 50 --aps 1 --tim 1 --host localhost --port 8080 --if rmr
265
266   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --if rmr
267
268   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --if http
269
270   Endurance test example: cli/alarm-cli perf --prf 2 --nal 50 --aps 1 --tim 1 --host localhost --port 8080 --if rmr
271
272 Get alerts from Prometheus Alert Manager: 
273
274  .. code-block:: none
275
276   Syntax: cli/alarm-cli alerts --active --inhibited --silenced --unprocessed --host [--port]
277
278   Example: cli/alarm-cli alerts --active true --inhibited true --silenced true --unprocessed true --host 10.102.36.121 --port 9093
279
280
281 REST interface usage guide
282 --------------------------
283
284 REST interface offers all the same services plus some more that are available via CLI. The CLI also uses the REST interface to implement the services it offers.
285
286 Below are examples for REST interface. Curl tool is used to send REST commands.
287
288  Check active alarms:
289
290    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/active" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
291
292  Check alarm history:
293
294    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/history" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
295
296  Raise alarm:
297
298    Example: curl -X POST "http://localhost:8080/ric/v1/alarms" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"managedObjectId\": \"RIC\", \"applicationId\": \"UEEC\", \"specificProblem\": 8007, \"perceivedSeverity\": \"CRITICAL\", \"additionalInfo\": \"-\", \"identifyingInfo\": \"INFO-1\", \"AlarmAction\": \"RAISE\", \"AlarmTime\": 0}"
299
300  Clear alarm:
301
302    Example: curl -X DELETE "http://localhost:8080/ric/v1/alarms" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"managedObjectId\": \"RIC\", \"applicationId\": \"UEEC\", \"specificProblem\": 8007, \"perceivedSeverity\": \"\", \"additionalInfo\": \"-\", \"identifyingInfo\": \"INFO-1\", \"AlarmAction\": \"CLEAR\", \"AlarmTime\": 0}"
303
304  Get configuration of maximum active alarms and maximum alarms in alarm history:
305
306    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/config" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
307
308  Configure maximum active alarms and maximum alarms in alarm history:
309
310    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/config" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"maxactivealarms\": 1000, \"maxalarmhistory\": 5000}"
311
312  Get all alarm definitions:
313
314    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
315
316  Get an alarm definition:
317
318    Syntax: curl -X GET "http://localhost:8080/ric/v1/alarms/define/{alarmId}" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
319
320    Example: curl -X GET "http://localhost:8080/ric/v1/alarms/define/8007" -H  "accept: application/json" -H "Content-Type: application/json" -d "{}"
321
322  Add one new alarm definition:
323
324    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\, \"raiseDelay\": 1, \"clearDelay\": 1"}]}"
325
326  Add two new alarm definitions:
327
328    Example: curl -X POST "http://localhost:8080/ric/v1/alarms/define" -H "accept: application/json" -H "Content-Type: application/json" -d "{\"alarmdefinitions\": [{\"alarmId\": 8007, \"alarmText\": \"E2 CONNECTIVITY LOST TO E-NODEB\", \"eventtype\": \"Communication error\", \"operationinstructions\": \"Not defined\, \"raiseDelay\": 0, \"clearDelay\": 0"},{\"alarmId\": 8008, \"alarmText\": \"ACTIVE ALARM EXCEED MAX THRESHOLD\", \"eventtype\": \"storage warning\", \"operationinstructions\": \"Clear alarms or raise threshold\", \"raiseDelay\": 0, \"clearDelay\": 0}]}"
329
330  Delete one existing alarm definition:
331
332    Syntax: curl -X DELETE "http://localhost:8080/ric/v1/alarms/define/{alarmId}" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
333
334    Example: curl -X DELETE "http://localhost:8080/ric/v1/alarms/define/8007" -H "accept: application/json" -H "Content-Type: application/json" -d "{}"
335
336
337 RMR interface usage guide
338 -------------------------
339 Through RMR interface application can only raise and clear alarms. RMR message payload is similar JSON message as in above REST interface use cases.
340
341  Supported events via RMR interface
342   
343   - Raise alarm
344   - Clear alarm
345   - Reraise alarm
346   - ClearAll alarms (not supported yet)
347
348
349 Example on how to use the API from Golang code
350 ----------------------------------------------
351 Alarm library functions can be used directly from Golang code. Rising and clearing alarms goes via RMR interface from alarm library to Alarm Manager.
352
353
354 .. code-block:: none
355
356  package main
357
358  import (
359     alarm "gerrit.o-ran-sc.org/r/ric-plt/alarm-go/alarm"
360  )
361
362  func main() {
363     // Initialize the alarm component
364     alarmer, err := alarm.InitAlarm("my-pod", "my-app")
365
366     // Create a new Alarm object (SP=8004, etc)
367     alarm := alarmer.NewAlarm(8004, alarm.SeverityMajor, "NetworkDown", "eth0")
368
369     // Raise an alarm (SP=8004, etc)
370     err := alarmer.Raise(alarm)
371
372     // Clear an alarm (SP=8004)
373     err := alarmer.Clear(alarm)
374
375     // Re-raise an alarm (SP=8004)
376     err := alarmer.Reraise(alarm)
377
378     // Clear all alarms raised by the application - (not supported yet)
379     err := alarmer.ClearAll()
380  }
381  
382  
383 Example VES event
384 -----------------
385
386 .. code-block:: none
387
388  INFO[2020-06-08T07:50:10Z]
389  {
390    "event": {
391      "commonEventHeader": {
392        "domain": "fault",
393        "eventId": "fault0000000001",
394        "eventName": "Fault_ricp_E2 CONNECTIVITY LOST TO G-NODEB",
395        "lastEpochMicrosec": 1591602610944553,
396        "nfNamingCode": "ricp",
397        "priority": "Medium",
398        "reportingEntityId": "035EEB88-7BA2-4C23-A349-3B6696F0E2C4",
399        "reportingEntityName": "Vespa",
400        "sequence": 1,
401        "sourceName": "RIC",
402        "startEpochMicrosec": 1591602610944553,
403        "version": 3
404      },
405
406      "faultFields": {
407        "alarmCondition": "E2 CONNECTIVITY LOST TO G-NODEB",
408        "eventSeverity": "MAJOR",
409        "eventSourceType": "virtualMachine",
410        "faultFieldsVersion": 2,
411        "specificProblem": "eth12",
412        "vfStatus": "Active"
413      }
414    }
415  }
416  INFO[2020-06-08T07:50:10Z] Schema validation succeeded