1 module o-ran-sc-common-alarms-v1 {
3 namespace "urn:o-ran-sc:yang:o-ran-sc-common-alarms-v1";
11 "O-RAN Software Community";
15 "This module defines the alarm identities for the O-RAN-SC Components.
17 Copyright 2021 the O-RAN Software Community.
19 Licensed under the Apache License, Version 2.0 (the 'License');
20 you may not use this file except in compliance with the License.
21 You may obtain a copy of the License at
23 http://www.apache.org/licenses/LICENSE-2.0
25 Unless required by applicable law or agreed to in writing, software
26 distributed under the License is distributed on an 'AS IS' BASIS,
27 WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
28 See the License for the specific language governing permissions and
29 limitations under the License.";
33 "The namespace was updated according to O-RAN-SC yang guidelines.
34 The namespace must end with the full module name.";
36 "https://jira.o-ran-sc.org/browse/OAM-168";
42 "O-RAN-OAM-Interface-Specification (O1)";
45 identity alarm-type-id {
46 base al:alarm-type-id;
48 "An abstract alarm type use for all O-RAN-SC alarm types which are
49 common across the O-RAN managed functions.";
52 identity smo-o1-ves-collector-not-reachable {
55 "The configured VES end-point for asynchronous messages is not reachable.
57 1) Verify the VES configuration on the O-RAN component.
58 2) Verify the connectivity between the O-RAN component and the
59 SMO in terms of routing and firewall settings along the path.
60 3) Check the credentials of the O-RAN component (user, password,
61 certificate). Did changes happen on SMO level recently?";